Setting ERPS timers

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter ERPS ring view.

erps ring ring-id

N/A

3. Enter ERPS instance view.

instance instance-id

N/A

4. Set the guard timer.

timer guard guard-value

By default, the guard timer is 500 milliseconds.

5. Set the hold-off timer.

timer hold-off hold-off-value

By default, the hold-off timer is 0 milliseconds.

6. Set the WTR timer.

timer wtr wtr-value

By default, the WTR timer is 5 minutes.