issu run switchover
Use issu run switchover to perform an ISSU switchover.
Syntax
issu run switchover
Views
User view
Predefined user roles
network-admin
mdc-admin
Usage guidelines
Perform an ISSU switchover to upgrade the master after you execute the issu load command to upgrade the subordinate device.
The issu load command separates the upgraded subordinate device from the existing IRF fabric to form a new IRF fabric. When you execute the issu run switchover command, the master in the old IRF fabric reboots to join the new IRF fabric as a subordinate member.
Before you execute the issu run switchover command on the old master, make sure the new master has finished synchronizing its configuration and status data with the old master. To examine the synchronization progress, use the display device and display system internal ha service-group commands on the new IRF fabric. The synchronization is completed if the following conditions are met:
All cards of the device are in Normal state.
The Action field of the display system internal ha service-group command is 0 for each service.
Examples
# Perform an ISSU switchover.
<Sysname> issu run switchover Upgrade summary according to following table: flash:/BOOT-R0202.bin Running Version New Version Release 0201 Release 0202 flash:/SYSTEM-R0202.bin Running Version New Version Release 0201 Release 0202 Chassis Slot Switchover Way 2 10 Global active standby MPU switchover Upgrading software images to compatible versions. Continue? [Y/N]:y
Table 26: Command output
Field | Description |
---|---|
Switchover Way | Switchover method:
|
For more information about the command output, see Table 22.
Related commands
issu load