display fcs database

Use display fcs database to display the local FCS database information, including IE attributes and port attributes.

Syntax

display fcs database [ vsan vsan-id ]

Views

Any view

Predefined user roles

network-admin

network-operator

mdc-admin

mdc-operator

Parameters

vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command display the FCS database information in all VSANs.

Examples

# Display the FCS database information in all VSANs.

<Sysname> display fcs database
FCS Local Database in VSAN 1:
  IE WWN                   : 10:00:00:11:22:00:01:01
  Domain ID                : 0x01
  Management address list  : snmp://192.168.6.100
                             snmp://192.168.0.100
  Fabric name              : 10:01:00:11:22:00:01:01
  Logical name             : IE-Sysname1
  Information list         : HPE#HPE FlexFabric 7910 Switch Chassis#Version 7.1.045,
                             Release 2150
  IE ports:
    Interface   Port WWN                  Port type  Attached port WWNs
    Vfc2        2f:15:01:11:22:00:01:01   F_Port     2f:15:01:11:22:00:01:02
                                                     2f:15:01:11:22:00:01:03
                                                     2f:15:01:11:22:00:01:04
    Vfc1        38:00:00:11:22:00:01:01   E_Port     38:00:00:11:22:00:01:02

  IE WWN                   : 10:00:00:11:22:00:01:02
  Domain ID                : 0x02
  Management address list  : snmp://192.168.6.101
  Fabric name              : 10:01:00:11:22:00:01:01
  Logical name             : IE-Sysname2
  Information list         : HPE#HPE FlexFabric 7910 Switch Chassis#Version 7.1.045,
                             Release 2150
  IE ports:
    Interface   Port WWN                  Port type  Attached port WWNs
    -           2f:15:01:11:22:00:01:01   F_Port     2f:15:01:11:22:00:01:02
    -           38:00:00:11:22:00:01:01   E_Port     38:00:00:11:22:00:01:02


FCS Local Database in VSAN 2:
  IE WWN                   : 10:00:00:11:22:00:01:01
  Domain ID                : 0x01
  Management address list  : snmp://192.168.6.100
                             snmp://192.168.0.100
  Fabric name              : 10:02:00:11:22:00:01:01
  Logical name             : IE-Sysname
  Information list         : HPE#HPE FlexFabric 7910 Switch Chassis#Version 7.1.045,
                             Release 2150
  IE ports:
    Interface    Port WWN                  Port type  Attached port WWNs

Table 34: Command output

Field

Description

Management address list

  • snmp://192.168.6.100—SNMP is supported by the IE, and the management IP address is 192.168.6.100.

  • Unknown—No management IP address is obtained from the IE.

  • NA—No management IP address is configured on the IE.

Fabric name

Name of the fabric where the IE resides.

Unknown indicates that the fabric name is not obtained from the IE.

Logical name

Device name of the IE.

Unknown indicates that the device name is not obtained from the IE.

Information list

Includes vendor name, model name/number, and release code.

Unknown indicates that the information list is not obtained from the IE.

Interface

Interface name.

The interface name is displayed for only interfaces on the local IE. For interfaces on non-local IEs, a hyphen (-) is displayed.

Port type

Port mode: E_Port or F_Port.

Unknown is displayed for port modes other than E_Port and F_Port.

Attached port WWNs

WWNs of connected ports.

NA indicates that the port does not connect to any ports.

Related commands

fcs discovery start