Configuring the collaboration function
Collaboration is implemented by establishing reaction entries to monitor the detection results of a test group. If the number of consecutive probe failures reaches the threshold, the configured action is triggered.
To configure the collaboration function:
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter NQA test group view. | nqa entry admin-name operation-tag | N/A |
3. Enter test type view of the test group. | type { dhcp | dlsw | dns | ftp | http | icmp-echo | snmp | tcp | udp-echo } | The collaboration function is not supported in UDP jitter and voice tests. |
4. Configure a reaction entry. | reaction item-number checked-element probe-fail threshold-type consecutive consecutive-occurrences action-type trigger-only | Not created by default. You cannot modify the content of an existing reaction entry. |
5. Exit to system view. | quit | N/A |
6. Configure a track entry and associate it with the reaction entry of the NQA test group. | track entry-number nqa entry admin-name operation-tag reaction item-number | Not created by default. |