Configuring the collaboration function

Collaboration is implemented by establishing reaction entries to monitor the detection results of a test group. If the number of consecutive probe failures reaches the threshold, the configured action is triggered.

To configure the collaboration function:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter NQA test group view.

nqa entry admin-name operation-tag

N/A

3. Enter test type view of the test group.

type { dhcp | dlsw | dns | ftp | http | icmp-echo | snmp | tcp | udp-echo }

The collaboration function is not supported in UDP jitter and voice tests.

4. Configure a reaction entry.

reaction item-number checked-element probe-fail threshold-type consecutive consecutive-occurrences action-type trigger-only

Not created by default.

You cannot modify the content of an existing reaction entry.

5. Exit to system view.

quit

N/A

6. Configure a track entry and associate it with the reaction entry of the NQA test group.

track entry-number nqa entry admin-name operation-tag reaction item-number

Not created by default.