Configuring DLSw tests

DLSw tests of an NQA test group are used to test the response time of a DLSw device.

Before you start DLSw tests, enable the DLSw function on the peer device.

To configure DLSw tests:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Enter NQA test group view.

nqa entry admin-name operation-tag

N/A

3. Configure the test type as DLSw, and enter test type view.

type dlsw

N/A

4. Configure the destination address of probe packets.

destination ip ip-address

By default, no destination IP address is configured.

5. Configure the source IP address of probe packets.

source ip ip-address

Optional.

By default, no source IP address is specified.

The source IP address must be the IP address of a local interface. The local interface must be up. Otherwise, no probe packets can be sent out.

6. Configure optional parameters.

See ""

Optional.