lldp timer tx-interval
Syntax
lldp timer tx-interval interval
undo lldp timer tx-interval
View
System view
Default level
2: System level
Parameters
interval: Sets the LLDP frame transmission interval, in the range of 5 to 32768 seconds.
Description
Use lldp timer tx-interval to set the LLDP frame transmission interval.
Use undo lldp timer tx-interval to restore the default.
By default, the LLDP frame transmission interval is 30 seconds.
It is a good practice to set the LLDP frame transmission interval to be no less than four times the LLDP frame transmission delay.
If the LLDP frame transmission interval is less than the LLDP frame transmission delay, the device uses the LLDP frames transmission delay as the transmission interval.
Related commands: lldp timer tx-delay.
Examples
# Set the LLDP frame transmission interval to 20 seconds.
<Sysname> system-view [Sysname] lldp timer tx-interval 20