No audit results on UBA
To resolve the problem:
Check the intranet information on the Server Configuration page.
If the IP address of the host that UBA monitors does not belong to the intranet network, the IP address will not be monitored.
To add the monitored IP address:
In the Intranet Monitor Information area, enter the IP address of the monitored host as intranet information.
Click Add, as shown in Figure 3.
The IP address is displayed in the Intranet Information area.
Click Deploy.
Log in to the IMC database and check whether the tbl_flow_YYMMDDHH table exists.
If the table exists, make sure the time setting and time zone of the device are consistent with the setting on the NTA/UBA server.
If the table does not exist, the NTA/UBA server cannot receive NetFlow data. For more information about resolving the problem, see "No NetFlow data on the NTA/UBA server."
If the problem persists, contact HPE Support.