Unable to create RCFC link due to incorrect connection or zoning
HPE SSMC displays an error message stating that it is unable to create an RCFC link between the selected systems. Verify the connection and zoning setup.
NOTE:
RCFC ports are supported in HPE Primera OS 4.1 or later and HPE SSMC 3.6.1 or later.
Solution 1Cause
Action
Only one system has been selected.
Select another system and then select a port.
Solution 2Cause
Action
The selected systems are not in the same SAN configuration.
Choose a system from the same SAN zone.
Solution 3Cause
Action
The RCFC ports of the connecting storage systems are not physically zoned together.