Automatic resynchronization for asynchronous periodic mode Remote Copy groups

Asynchronous periodic mode Remote Copy groups automatically synchronize based on the synchronization period you choose.

NOTE:

Make sure that the network link you use is large enough to accept all the transmitted data for the duration of the synchronization period.

  • The delta resynchronization period is set when the source Remote Copy group is created.

  • You can adjust the resynchronization period anytime after you create the Remote Copy group, including after you start Remote Copy operations for the group.

  • The resynchronization schedule starts its countdown from the current resynchronization start time.

    For example, the synchronization period is set to 10 minutes. A synchronization begins at 1:00 p.m. and completes. The next synchronization begins at 1:10 p.m., the next at 1:20 p.m., and so on.

  • If a resynchronization is delayed, the next resynchronization starts after the specified synchronization period.

    For example, the synchronization period is set to 10 minutes. A resynchronization begins at 1:00 p.m. and takes 12 minutes to complete. The next resynchronization begins at 1:12 p.m. If that resynchronization takes 2 minutes to complete (within the 10 minute interval), the next resynchronization begins at 1:22 p.m., 10 minutes after the previous resynchronization.