Physically connecting the RCFC ports between storage systems
Physically cable the RCFC ports between storage systems. This procedure describes the minimum cabling for a 2-node system to another 2-node system.
TIP:
Create a diagram of the physical Remote Copy configuration.
Prerequisites
Installed a supported Fibre Channel HBA with available ports on each node to be used for RCFC for each storage system.
Procured an appropriate FC cable based on the speed and distance the connection is intended to support. See the SAN design Reference Guide.
Set up an FC SAN infrastructure.
Procedure
Site 1
-
For the first node (for example, Node 0):
- Insert one end of the FC cable on the RCFC port.
- Insert the other end of the FC cable into a port on a SAN switch.
-
For the second node (for example, Node 1):
- Insert one end of the FC cable on the RCFC port.
- Insert the other end of the FC cable into a port on another SAN switch.
Site 2
- Repeat this procedure for Site 2.