Using real time reports

Procedure
  1. On the main menu, select System Reporter > Reports.
  2. In the list pane, set the data types filter for Real Time.
  3. In the list pane, select the real time report, and then do one of the following:
    • Select Edit on the Actions menu. Follow the instructions on the dialog that opens.

    • Select Start real time or Stop real time on the Actions menu, or click the Start or Stop icons on the detail pane. The action is immediately applied to the report.

Tips:

General

  • You can specify the data-collection polling interval when you create or edit a real time report.

  • Hewlett Packard Enterprise recommends Chrome browsers for viewing the real time reports.

  • Zooming on a real time report zooms in both the X and Y axis.

Objects

  • If you select the All objects option on the Add objects dialog, you cannot select individual objects.

  • If you select the Select objects option and plot only the aggregated series, you can include up to 100 objects. If you select the Select objects option and plot only individual series, you can include up to 10 objects. If you select the Select objects option and plot both the aggregated series and individual series, you can include up to 9 objects.

Restarts

  • If you stop the report while viewing a real time report and then restart the report, the chart is not cleared. The report appends to the existing charts.

  • If you stop a real time report and then revisit the report, the chart is cleared. Restarting the report will draw the charts based on the new start time.

  • If you zoom into a real time report and then reset the zoom, there will not be any change in the charts. The existing chart appears again.

  • If the HPE SSMC server is stopped and restarted while you are viewing a real time report, you must select Start real time on the Actions menu to restart the plotting.

  • The data-collection timeout for a real time report is 30 minutes. For example, if you are viewing a real time report and switch to a different report or screen, and you do not return to the report, data collection for the report stops after 30 minutes. If you return to the report after 30 minutes, you must click Start real time on the Actions menu to restart the report and data collection.