Remote Copy over Fibre Channel (RCFC) network transport requirements

For RCFC configurations, each link between storage systems is a physical link between a controller node on one storage system and a controller node on the other storage system in the configuration.

To use a Fibre Channel network for Remote Copy, the following requirements must be met.

  • Utilizing like node pairs (node 0 and 1 is an example of a node pair) on each storage system is recommended, but is not a requirement.

  • FC SAN is used to connect the storage systems (direct connect FC is not supported).

  • Each pair of RCFC ports between the primary and secondary system must be in their own zone. Fabric zones cannot be shared. A single initiator to a single port configuration and a dual fabric layout is preferred.

    For example, only two ports per zone are allowed as shown in Zoning RCFC node pairs . Each zone must contain one port from the primary site and a second port from the secondary site.

  • Requirements in the SAN design Reference Guide are met.

  • Interrupt coalescing must be disabled on the RCFC ports.