Recommended storage disks specifications

The following table provides information on the storage disks specifications that have been validated as part of a blueprint, reason to consider them, and customization options.

Components Validated Configuration Blueprint Design Consideration Customization Option

Master node (Intel-based)

The master nodes are HPE ProLiant DL360 Gen10 Servers with dual socket Gen2 Intel Xeon scalable family processors.

  • 2 x 2.4TB SAS HDD 12G Enterprise 10K SFF

  • This HDD provides the highest levels of performance and reliability for mission-critical and I/O-intensive applications.

  • Use Performance RAID Controller-HPE Smart Array P408i-a SR G10 Controller

  • Supported RAID: Raid 1, Minimum Drive count: 2

Worker node (Intel-based)

The worker nodes are HPE ProLiant DL360 Gen10 Servers with dual socket  Gen2 Intel Xeon scalable family processors.

  • 4 x 2.4TB SAS HDD 12G Enterprise 10K SFF

  • This HDD provides the highest levels of performance and reliability for mission-critical and I/O-intensive applications.

  • Use Performance RAID Controller-HPE Smart Array P408i-a SR G10 Controller

  • Supported RAID: Raid 1, Minimum Drive count: 2

Master node (AMD-based)

The master nodes are HPE ProLiant DL325 Gen10 Plus Servers with single socket AMD EPYC family processors.

  • 4 x 1.2TB SAS HDD 12G Enterprise 10K SFF

  • This HDD provides the highest levels of performance and reliability for mission-critical and I/O-intensive applications.

  • Use Performance RAID Controller-HPE Smart Array P408i-a SR G10 Controller

  • Supported RAID: Raid 1, Minimum Drive count: 2

Worker node (AMD-based)

The worker nodes are HPE ProLiant DL325 Gen10 Plus Servers with single socket AMD EPYC family processors.

  • 2 x 1.2TB SAS HDD 12G Enterprise 10K SFF

  • This HDD provides the highest levels of performance and reliability for mission-critical and I/O-intensive applications.

  • Use Performance RAID Controller-HPE Smart Array P408i-a SR G10 Controller

  • Supported RAID: Raid 1, Minimum Drive count: 2