snmp-agent trap enable evi-isis
Use snmp-agent trap enable evi-isis to enable EVI IS-IS notifications.
Use undo snmp-agent trap enable evi-isis to disable EVI IS-IS notifications.
Syntax
snmp-agent trap enable evi-isis [ adjacency-state-change | area-mismatch | buffsize-mismatch | id-length-mismatch | link-disconnect | lsp-parse-error | lsp-size-exceeded | max-seq-exceeded | maxarea-mismatch | new-ded | own-lsp-purge | protocol-support | rejected-adjacency | skip-sequence-number | topology-change | version-skew ] *
undo snmp-agent trap enable evi-isis [ adjacency-state-change | area-mismatch | buffsize-mismatch | id-length-mismatch | link-disconnect | lsp-parse-error | lsp-size-exceeded | max-seq-exceeded | maxarea-mismatch | new-ded | own-lsp-purge | protocol-support | rejected-adjacency | skip-sequence-number | topology-change | version-skew ] *
Default
EVI IS-IS notification sending is enabled.
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
adjacency-state-change: Specifies notifications about EVI IS-IS adjacency status changes.
area-mismatch: Specifies notifications about area address mismatches between hello packets.
buffsize-mismatch: Specifies notifications about buffer size mismatches for LSPs.
id-length-mismatch: Specifies notifications about system ID length mismatches of EVI IS-IS packets.
link-disconnect: Specifies notifications about EVI link failures.
lsp-parse-error: Specifies notifications about LSP parse failures.
lsp-size-exceeded: Specifies notifications about propagation failures caused by oversized LSPs.
max-seq-exceeded: Specifies notifications about attempts to exceed with the maximum LSP sequence number.
maxarea-mismatch: Specifies notifications about maximum area address mismatches of hello packets.
new-ded: Specifies notifications about the device's being elected as the DED.
own-lsp-purge: Specifies notifications about attempts to remove the local LSP.
protocol-support: Specifies notifications about supported-protocol mismatches for non-pseudo node LSPs.
rejected-adjacency: Specifies notifications about adjacency creation failures.
skip-sequence-number: Specifies notifications about LSP sequence number duplications.
topology-change: Specifies notifications about edge device topology changes at the local site. This notification will not be sent if a new-ded notification has been sent for the same vent.
version-skew: Specifies notifications about hello packet version mismatches.
Usage guidelines
If you do not specify a notification, this command enables all EVI IS-IS notifications.
To report critical EVI IS-IS events to an NMS, enable SNMP notifications for EVI IS-IS. For EVI IS-IS event notifications to be sent correctly, you must also configure SNMP as described in Network Management and Monitoring Configuration Guide.
Examples
# Enable EVI IS-IS adjacency status change notifications.
<Sysname> system-view [Sysname] snmp-agent trap enable evi-isis adjacency-state-change