Configuring the monitor port for a local mirroring group
On the source device, configure the tunnel interface as the monitor port. On the destination device, configure the port that connects to a data monitoring device as the monitor port.
To configure the monitor port for a mirroring group, use one of the following methods:
Configure the monitor port for the mirroring group in system view.
Assign a port to a mirroring group as the monitor port in interface view.
Configuration restrictions and guidelines
When you configure the monitor port for a local mirroring group, follow these restrictions and guidelines:
Do not enable the spanning tree feature on the monitor port.
Use a monitor port only for port mirroring, so the data monitoring device receives only the mirrored traffic.
Configuring the monitor port in system view
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Configure the monitor port for a local mirroring group. | mirroring-group group-id monitor-port interface-type interface-number | By default, no monitor port is configured for a local mirroring group. |
Configuring the monitor port in interface view
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter interface view. | interface interface-type interface-number | N/A |
3. Configure the port as the monitor port for a local mirroring group. | mirroring-group group-id monitor-port | By default, a port does not act as the monitor port for any local mirroring groups. |