Creating an RMON Ethernet statistics entry
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Enter Ethernet interface view. | interface interface-type interface-number | N/A |
3. Create an RMON Ethernet statistics entry. | rmon statistics entry-number [ owner text ] | By default, no RMON Ethernet statistics entry exists. You can create only one RMON statistics entry for an Ethernet interface. |