Configuring the collaboration feature
Collaboration is implemented by associating a reaction entry of an NQA operation with a track entry. The reaction entry monitors the NQA operation. If the number of operation failures reaches the specified threshold, the configured action is triggered.
To configure the collaboration feature:
Step | Command | Remarks |
---|---|---|
1. Enter system view. | system-view | N/A |
2. Create an NQA operation and enter NQA operation view. | nqa entry admin-name operation-tag | By default, no NQA operations exist. |
3. Specify an NQA operation type and enter its view. | type { dhcp | dlsw | dns | ftp | http | icmp-echo | snmp | tcp | udp-echo } | The collaboration feature is not available for the ICMP jitter, path jitter, UDP tracert, UDP jitter, or voice operations. |
4. Configure a reaction entry. | reaction item-number checked-element probe-fail threshold-type consecutive consecutive-occurrences action-type trigger-only | By default, no reaction entry is configured. You cannot modify the content of an existing reaction entry. |
5. Return to system view. | quit | N/A |
6. Associate Track with NQA. | See High Availability Configuration Guide. | N/A |
7. Associate Track with an application module. | See High Availability Configuration Guide. | N/A |