Configuring the collaboration feature

Collaboration is implemented by associating a reaction entry of an NQA operation with a track entry. The reaction entry monitors the NQA operation. If the number of operation failures reaches the specified threshold, the configured action is triggered.

To configure the collaboration feature:

Step

Command

Remarks

1. Enter system view.

system-view

N/A

2. Create an NQA operation and enter NQA operation view.

nqa entry admin-name operation-tag

By default, no NQA operations exist.

3. Specify an NQA operation type and enter its view.

type { dhcp | dlsw | dns | ftp | http | icmp-echo | snmp | tcp | udp-echo }

The collaboration feature is not available for the ICMP jitter, path jitter, UDP tracert, UDP jitter, or voice operations.

4. Configure a reaction entry.

reaction item-number checked-element probe-fail threshold-type consecutive consecutive-occurrences action-type trigger-only

By default, no reaction entry is configured.

You cannot modify the content of an existing reaction entry.

5. Return to system view.

quit

N/A

6. Associate Track with NQA.

See High Availability Configuration Guide.

N/A

7. Associate Track with an application module.

See High Availability Configuration Guide.

N/A