circuit-cost

Use circuit-cost to configure a global SPBM link metric value.

Use undo circuit-cost to restore the default.

Syntax

circuit-cost value

undo circuit-cost

Default

No global SPBM link metric value is configured.

Views

SPBM view

Predefined user roles

network-admin

Parameters

value: Specifies a link metric value in the range of 1 to 16777215.

Usage guidelines

The following methods are available for you to assign a link metric value to an interface:

The system chooses a link metric value for an interface in order of interface-specific value, global value, and autocalculated value.

Examples

# Set the global SPBM link metric value to 11.

<Sysname> system-view
[Sysname] spbm
[Sysname-spbm] circuit-cost 11

Related commands