display spbm ect

Use display spbm ect to display B-VLAN to ECT algorithm mappings by ECT algorithm index.

Syntax

display spbm ect [ ect-index ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

ect-index: Specifies an ECT algorithm index in the range of 1 to 16. If you do not specify an ECT algorithm, the command displays information for all ECT algorithms.

Examples

# Display information about all ECT algorithms.

<Sysname> display spbm ect
ECT-1:
    Algorithm: 00-80-c2-01     Mask: 0x00
    Active B-VLANs: 1-10
    Inactive B-VLANs: 31-4094
ECT-2:
    Algorithm: 00-80-c2-02     Mask: 0xff
    Active B-VLANs: 11-20
    Inactive B-VLANs: 21-30
ECT-3:
    Algorithm: 00-80-c2-03     Mask: 0x88
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-4:
    Algorithm: 00-80-c2-04     Mask: 0x77
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-5:
    Algorithm: 00-80-c2-05     Mask: 0x44
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-6:
    Algorithm: 00-80-c2-06     Mask: 0x33
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-7:
    Algorithm: 00-80-c2-07     Mask: 0xcc
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-8:
    Algorithm: 00-80-c2-08     Mask: 0xbb
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-9:
    Algorithm: 00-80-c2-09     Mask: 0x22
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-10:
    Algorithm: 00-80-c2-0a     Mask: 0x11
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-11:
    Algorithm: 00-80-c2-0b     Mask: 0x66
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-12:
    Algorithm: 00-80-c2-0c     Mask: 0x55
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-13:
    Algorithm: 00-80-c2-0d     Mask: 0xaa
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-14:
    Algorithm: 00-80-c2-0e     Mask: 0x99
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-15:
    Algorithm: 00-80-c2-0f     Mask: 0xdd
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A
ECT-16:
    Algorithm: 00-80-c2-10     Mask: 0xee
    Active B-VLANs: N/A
    Inactive B-VLANs: N/A

Table 10: Command output

Field

Description

Algorithm

ECT algorithm.

Mask

ECT algorithm mask.

Active B-VLANs

Active B-VLANs mapped to the ECT algorithm. Active B-VLANs are VLANs mapped to MSTI 4092.

This field displays N/A if no active B-VLANs are mapped to the algorithm.

Inactive B-VLANs

Inactive B-VLANs mapped to the ECT algorithm. This field displays N/A if no inactive B-VLANs are mapped to the algorithm.