trill timer holding-multiplier
Use trill timer holding-multiplier to configure the Hello multiplier.
Use undo trill timer holding-multiplier to restore the default.
Syntax
trill timer holding-multiplier count
undo trill holding-multiplier
Default
The Hello multiplier is 3.
Views
Layer 2 Ethernet interface view
Layer 2 aggregate interface view
Predefined user roles
network-admin
mdc-admin
Parameters
count: Specifies a multiplier in the range of 2 to 1000.
Usage guidelines
The adjacency holding time is obtained by multiplying the Hello interval by the Hello multiplier. The RB advertises the adjacency holding time to neighbors through Hello frames. If a neighbor does not receive any Hello frames from the RB within the adjacency holding time, it removes the TRILL adjacency with the RB.
The adjacency holding time cannot exceed 65535 seconds.
Configuration in Layer 2 Ethernet interface view takes effect only on the current port. Configuration in Layer 2 aggregate interface view takes effect on the current interface and its member ports. Configuration on the member port of an aggregate interface takes effect after the member port leaves the aggregation group.
Examples
# Set the Hello multiplier to 6 on .
<Sysname> system-view [Sysname] interface [Sysname-] trill timer holding-multiplier 6
Related commands
trill timer hello