display trill brief

Use display trill brief to display brief TRILL information.

Syntax

display trill brief

Views

Any view

Predefined user roles

network-admin

network-operator

mdc-admin

mdc-operator

Examples

# Display brief TRILL information.

<Sysname> display trill brief
Network entity: 00.00a0.fc00.5806.00
Nickname: 0xfa1b
Nickname priority: 64
Tree-root priority: 32768
Cost style: Wide
Maximum allowed LSP received: 1492
Maximum allowed LSP originated: 1458
Maximum unicast load-balancing: 8
Overload status: None
Overload remaining time: N/A
Device role: Normal
Timers:
  LSP-max-age: 1200s
  LSP-refresh: 900s
  Interval between SPFs: 10s  10ms  20ms

Table 2: Command output

Field

Description

Network entity

Name of the network entity.

Nickname

Nickname of the RB.

Nickname priority

Priority for the RB to hold the nickname.

Tree-root priority

Priority to be a TRILL distribution tree root.

Cost style

Cost type, which must be Wide.

Maximum allowed LSP received

Maximum length of LSPs that can be received.

Maximum allowed LSP originated

Maximum length of LSPs that can be originated.

Maximum unicast load-balancing

Maximum number of TRILL unicast equal-cost routes.

Overload status

Reason why the Overload bit is set:

  • Config—The Overload bit is set through configuration.

  • GR—The Overload bit is set during graceful restart.

  • GR/Config—The Overload bit is set through configuration during graceful restart of the Start type.

  • None—The Overload bit has not been set through configuration.

Device role

Device role:

  • Normal—Common RB.

  • Access—Access layer device.

  • Gateway—Gateway device.

Overload remaining time

Lifetime of the set Overload bit, in seconds. If the lifetime has not been set or the lifetime has expired, this field displays N/A.

Timers

TRILL timers.

LSP-max-age

LSP maximum age (in seconds).

LSP-refresh

LSP refresh interval (in seconds).

Interval between SPFs