show environment power-consumption

Syntax

show environment power-consumption [vsx-peer]

Not supported on the 6300 Switch Series.

Description

Shows the power being consumed by each management module, line card, and fabric card subsystem, and shows power consumption for the entire chassis.

Command context

Operator (>) or Manager (#)

Parameters

[vsx-peer]

Shows the output from the VSX peer switch. If the switches do not have the VSX configuration or the ISL is down, the output from the VSX peer switch is not displayed. This parameter is available on switches that support VSX.

Authority

Operators or Administrators or local user group members with execution rights for this command. Operators can execute this command from the operator context (>) only.

Usage

This command is only applicable to systems that support power consumption readings.

The power consumption values are updated once every minute.

The output of this command includes the following information:

Name

Shows the member number and slot number of the management module, line module, or fabric card module.

Type

Shows the type of module installed at the location specified by Name.

Description

Shows the product name and brief description of the module.

Usage

Shows the instantaneous power consumption of the module. Power consumption is shown in Watts.

Module Total Power Usage

Shows the total power consumption of all the modules listed. Power consumption is shown in Watts.

Chassis Total Power Usage

Shows the total instantaneous power consumed by the entire chassis, including modules and components that do not support individual power reporting. Power consumption is shown in Watts.

Chassis Total Power Available

Shows the total amount of power, in Watts, that can be supplied to the chassis.

Chassis Total Power Allocated

Shows total power, in Watts, that is allocated to powering the chassis and its installed modules.

Chassis Total Power Unallocated

Shows the total amount of power, in Watts, that has not been allocated to powering the chassis or its installed modules. This power can be used for additional hardware you install in the chassis.

Example

Showing the power consumption for an Aruba 6400 switch:
switch> show environment power-consumption
                                                                       Power
Name    Type                Description                                Usage
------------------------------------------------------------------------------
1/1     management-module   R0X31A 6400 Management Module              18 W
1/2     management-module                                              0 W
1/3     line-card-module                                               0 W
1/4     line-card-module    R0X39A 6400 48p 1GbE CL4 PoE 4SFP56 Mod    54 W
1/5     line-card-module                                               0 W
1/6     line-card-module    R0X39A 6400 48p 1GbE CL4 PoE 4SFP56 Mod    56 W
1/7     line-card-module    R0X39A 6400 48p 1GbE CL4 PoE 4SFP56 Mod    51 W
1/1     fabric-card-module  R0X24A 6405 Chassis                        71 W
 
 
Module Total Power Usage                                               250 W
Chassis Total Power Usage                                              294 W
 
Chassis Total Power Available                                          1800 W