Fan events

The following are the events related to fan.

Event ID: 201

Message
There are <count> total fans in subsystem <subsystem>
Category Fan
Severity Information

Event ID: 202

Message
subsystem <subsystem> setting fan speed control register to <speedval>: <value>
Category Fan
Severity Information

Event ID: 203

Message
Direction is <value>
Category Fan
Severity Information

Event ID: 204 (Severity: Warning)

Message
Fan Tray <FT_Num> was removed.
Category Fan
Severity Warning
Description Log event when a fan tray has been removed from the chassis

Event ID: 205

Message
Fan Tray <FT_Num> was inserted.
Category Fan
Severity Information
Description Log event when a fan tray is inserted into the chassis

Event ID: 206

Message
Fan module <FMod_Num> in Fan Tray <FT_Num> was removed.
Category Fan
Severity Information
Description Log event when a fan module has been removed from as fan tray

Event ID: 207

Message
Fan module <FMod_Num> in Fan Tray <FT_Num> was inserted.
Category Fan
Severity Information
Description Log event when a fan module is inserted in to a fan tray

Event ID: 208

Message
<NoOfFaultyFans> Faulty or Missing fans in system. Shutting down system now.
Category Fan
Severity Error
Description Log the error when the base subsystem thermal state goes to critical and system shutdown is initiated.

Event ID: 209 (Severity: Warning)

Message
<NoOfFaultyFans> Faulty or Missing fans in system. Shutting down system in <CountDownSeconds> seconds.
Category Fan
Severity Warning
Description Log the error when the base subsystem thermal state goes to critical due to missing fans

Event ID: 210 (Severity: Warning)

Message
System shutdown timer cancelled.
Category Fan
Severity Warning
Description When the faulty or missing fans are restored, the shutdown timer is cancelled

Event ID: 211

Message
<NoOfFaultyFans> Faulty or Missing fans in the system
Category Fan
Severity Error
Description Log error when there is a fan(s) fault.

Event ID: 212

Message
<Fault_Type> fan in fan tray <FanTrayIdx>, module <FanModuleIdx>.
Category Fan
Severity Error
Description List out the faulty or missing fans names.

Event ID: 213

Message
<FanName> Fan is <FanStatus>.
Category Fan
Severity Information
Description Log the fan status.

Event ID: 214 (Severity: Warning)

Message
Minimum number of fans required is <FanMinimum>. Current fan count is <FanCount>.
Category Fan
Severity Warning
Description Log when minimum number of fans are not present.