redundancy active-management

Syntax

redundancy active-management {management-module1 | management-module2 | standby}

Description

Specifies the management module that will become active at the next boot.

Command context

config

Parameters

management-module <1> | <2>

Specifies the redundant management module to enable.

standby

Specifies the standby management module.

Restrictions

  • The redundancy active-management command will fail if the other module is in a failed state or if VSF is enabled.

Usage

redundancy rapid-switchover <Seconds>

Specifies the rapid-switchover timer in seconds for L3 Hitless forwarding when used as a parameter for redundancy.

management-module

The selected active management module will continue as the active management module on boot until the user issues the command redundancy active-management which then changes the selected module.

redundancy switchover

Instructs the switch to immediately switch over to the standby management module.

Example

Show redundancy for management module.

Switch(config)# show redundancy

Configured Mode: Nonstop Switching 
Current Mode   : Nonstop Switching

Rapid Switchover Stale Timer : 90
Failovers     : 0
Last Failover : 
Preferred Active Management: management-module1

Slot Module Description                       State    SW Version    Boot Image
---- ---------------------------------------- -------- ------------- ----------
MM1  J9827A Management Module 5400Rzl2        Active   KB.16.xx.xxxx Primary  
MM2  J9827A Management Module 5400Rzl2        Standby  KB.16.xx.xxxx Primary