Chassis Events

The following are the events related to chassis.

Event ID: 67

Message
chassis: <SLOT_NAME> Removed
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a card in a slot is removed from an operational switch chassis. The <SLOT_NAME> in the format will indicate the slot from which the card was removed.

Event ID: 68

Message
chassis: <SLOT_NAME> Inserted
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a card is inserted into a slot in an operational system.

Event ID: 69 (Severity: Fatal)

Message
chassis: <SLOT_NAME> Hotswap Failure
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays whenever a slot in a switch chassis fails hotswap. The <SLOT_NAME> in the message will indicate the failed slot.

Event ID: 70 (Severity: Warning)

Message
Fan <STATUS_OK_OR_FAILURE>: Fan: <ID>  Failures: <NUM_FAILURES>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the software notices that a fan has failed or when a failed fan is no longer failing. The fan state is indicated as {failure | OK}. The fan is indicated as fan 1 or fan 2. The number of times the fan has failed will also be indicated. The fan fail LED will also be lit.

Event ID: 71 (Severity: Warning)

Message
Power Supply <STATUS_OK_OR_FAILURE>:  Supply: <ID>- Failures: <NUM_FAILURES>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the software notices that the RPS is failing or the RPS is present and the main power supply is failing or when a failed supply is no longer failing. The supply state will be indicated as {failure | OK}. The supply will be indicated as {Main | RPS}. The message will also indicate the number of times the supply has failed. The power fail LED will also be lit.

Event ID: 72 (Severity: Warning)

Message
chassis: <SLOT_NAME> Inactive: Module/Configuration mismatch
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a module has been inserted that is incompatable with the previous module in the indicated slot.

Event ID: 73 (Severity: Fatal)

Message
Chassis Backplane Power Fault: Chassis needs replacement.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description Chassis Backplane Power Fault: Chassis needs replacement.

Event ID: 274 (Severity: Warning)

Message
chassis: <SLOT_NAME> self test failure or unsupported module
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the indicated slot has failed selftest completely or when there are no usable ports on the slot.

Event ID: 278

Message
Module in slot <SLOT_NAME> not allowed
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description Re-enable the port since the BPDU protection auto-enable timer has expired.

Event ID: 371 (Severity: Warning)

Message
Port <PORT-NAME> self test failure ERR: <failure code>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the indicated port has failed selftest and is unusable.

Event ID: 372 (Severity: Warning)

Message
Invalid transceiver installed in Port <PORT-NAME>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the indicated port has an invalid transceiver installed.

Event ID: 373 (Severity: Warning)

Message
Boot ROM self test failure!
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the indicated port has an invalid transceiver installed.

Event ID: 374 (Severity: Warning)

Message
chassis: Lost Communication with <SLOT_NAME>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when Chassis Mgr. fails to receive a heartbeat response from a particular slave card.

Event ID: 375

Message
chassis: <SLOT_NAME> Downloading
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager begins downloading a new card.

Event ID: 376

Message
chassis: <SLOT_NAME> Download Complete
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager finishes downloading a new card.

Event ID: 377 (Severity: Warning)

Message
chassis: <SLOT_NAME> Download Failed
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays if chassis manager fails to download a new card.

Event ID: 422

Message
chassis: <SLOT_NAME> Available
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a slave card (ALpha/Gamma/Delta) goes into the state

Event ID: 423 (Severity: Warning)

Message
chassis: Unable to Download to <SLOT_NAME>. Please Remove Module
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays whenever a slave card has exceeded the number of download

Event ID: 424 (Severity: Warning)

Message
chassis: Module in <SLOT_NAME> not Supported or may be Faulty
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays whenever the master does not receive a download request from

Event ID: 425 (Severity: Warning)

Message
chassis: Backplane link to <SLOT_NAME> failed self test
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays whenever the master does not receive a download request from

Event ID: 549 (Severity: Warning)

Message
Insufficient power supplies to power <SLOT_NAME>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description chassis: Not enough power supplies to power <slot name>.

Event ID: 550

Message
Module Inserted
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager sees the module inserted.

Event ID: 551 (Severity: Warning)

Message
<SLOT_NAME> Module failed self test
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when chassis manager sees the module inserted.

Event ID: 552 (Severity: Warning)

Message
<Stacking Module> insertion detected: Reboot required
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when chassis manager sees the module inserted.

Event ID: 553 (Severity: Warning)

Message
Over-temperature detected. Failures: <MODULE_NUMBER>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the software notices that the RPS is failing or the RPS is present and the main power supply is failing or when a failed supply is no longer failing. The supply state will be indicated as {failure | OK}. The supply will be indicated as {Main | RPS}. The message will also indicate the number of times the supply has failed. The power fail LED will also be lit.

Event ID: 554 (Severity: Warning)

Message
<SLOT_NAME> NCI error IntReg=<INTERRUPT_REGISTER>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays if chassis manager fails to download a new card.

Event ID: 555 (Severity: Warning)

Message
chassis: RPS state: <ACTIVE/AVAILABLE/UNAVAILABLE/FAULTED>. Failures:
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays if chassis manager fails to download a new card.

Event ID: 556 (Severity: Warning)

Message
chassis: RPS state: <ACTIVE/AVAILABLE/UNAVAILABLE/FAULTED>. Failures:
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays if chassis manager fails to download a new card.

Event ID: 557

Message
Temperature back to normal. Failures:
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description Shows that the temp came back to normal. Sometimes message is overridden to print this: 'Temperature: Chassis Intake Air Normal'

Event ID: 558 (Severity: Warning)

Message
<SLOT_NAME>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description chassis: Display a log of a NMI event when log only.

Event ID: 559 (Severity: Warning)

Message
<SLOT_NAME>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description chassis: Display a log of a NMI event when log only.

Event ID: 568

Message
chassis: External Power Supply connected, supplying XXX W of YYY W max.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an EPS is successfully plugged in

Event ID: 569 (Severity: Warning)

Message
<SLOT_NAME>Ext Power Supply <GROUP_INDEX>: <pport> Failures: <port state>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an EPS reports an error condition to us

Event ID: 570 (Severity: Warning)

Message
chassis: External Power Supply connected but not responding.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an EPS is plugged in but we can't talk to it

Event ID: 572 (Severity: Warning)

Message
<SLOT_NAME> PoE usage has exceeded threshold of <start port> <end port>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the usage threshhold has been exceeded

Event ID: 573 (Severity: Warning)

Message
chassis: External Power Supply disconnected.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an EPS is unplugged

Event ID: 574

Message
<SLOT_NAME> PoE usage is below threshold of <start port> <end port>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when the usage threshhold has not been exceeded

Event ID: 575 (Severity: Warning)

Message
<SLOT_NAME> Ext Power Supply <GROUP_INDEX> not supported by switch code. Please update.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an EPS is plugged in and SW does not support it

Event ID: 576 (Severity: Warning)

Message
50V Power Supply <GROUP_INDEX> is . Failures: <port state>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an EPS is plugged in and SW does not support it

Event ID: 577 (Severity: Fatal)

Message
Ext Power Supply <GROUP_INDEX>: Failures: <port state>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when an EPS reports a fatal error condition to us

Event ID: 578 (Severity: Warning)

Message
chassis: Unrecoverable fault on PoE controller X.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when PoE contrller has a fault we can't recover from.

Event ID: 579

Message
<SLOT_NAME> Software update <port state> on PoE controller <GROUP_INDEX>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when PoE controller firmware is updated via software.

Event ID: 634

Message
Front panel clear button pressed; switch reset.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when clear button resets box

Event ID: 635

Message
Alternate password used to gain access.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when alt password is used.

Event ID: 731

Message
Ports <SLOT_NAME> Recognized
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a fix slot is detected as inserted in an operational system.

Event ID: 732 (Severity: Warning)

Message
Ports <SLOT_NAME> self test failure
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the indicated fix slot has failed selftest completely or when there are no usable ports on the fix slot.

Event ID: 733 (Severity: Warning)

Message
Lost Communication with Ports <SLOT_NAME>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when Chassis Mgr. fails to receive a heartbeat response from a particular fix slave card.

Event ID: 734

Message
Ports <PORT-NAME> Downloading
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager begins downloading a fix slot card.

Event ID: 735

Message
Ports <PORT-NAME> Download Complete
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager finishes downloading a fix slot card.

Event ID: 736 (Severity: Warning)

Message
Ports <PORT-NAME> Download Failed
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays if chassis manager fails to download a fix slot card.

Event ID: 737

Message
Ports <PORT-NAME> Ready
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a fix slot slave card (StrongBad) goes into the state

Event ID: 738 (Severity: Warning)

Message
Unable to Download to Ports <PORT-NAME>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays whenever a fix slot slave card has exceeded the number of download

Event ID: 739 (Severity: Warning)

Message
Ports <PORT-NAME> may be Faulty
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays whenever the master does not receive a download request from

Event ID: 740 (Severity: Warning)

Message
Backplane link to Ports <PORT-NAME> failed self test
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays whenever the backplane link to the fix slot failed selftest.

Event ID: 741

Message
<SLOT_NAME> Ports Present
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager sees the fix slot module inserted.

Event ID: 742 (Severity: Warning)

Message
Ports <SLOT_NAME> NCI Error IntReg=<INTERRUPT_REGISTER>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays if chassis manager fails to download a fix slot card.

Event ID: 817 (Severity: Warning)

Message
<SLOT_NAME> self test failure
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the indicated slot has failed selftest and is unusable.

Event ID: 818 (Severity: Warning)

Message
chassis: <SLOT_NAME> Invalid: This switch supports only "vl" modules
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the indicated slot is an invalid slot for vl.

Event ID: 819 (Severity: Warning)

Message
<SLOT_NAME> Invalid: Module not supported by this software version
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when indicated slot is is not supported by this software version.

Event ID: 829 (Severity: Warning)

Message
<SLOT_NAME>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description RTC: Battery Failure Detected -or; Clock Initializtion failure

Event ID: 928

Message
Fabric <slot index> active
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when a fabric blade is able to actively pass traffic

Event ID: 929 (Severity: Warning)

Message
Fabric <slot index> removed
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fabric blade is removed

Event ID: 930 (Severity: Warning)

Message
Slot link failure:  Fabric <MEMBER_NUMBER> has faulty link to <adjacent member number>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fault on a line card prevents it from connecting a link to a fabric. Error may be recoverable, but if persistant the linecard needs to be replaced.

Event ID: 931 (Severity: Warning)

Message
Fabric failure: link error between Fabric <MEMBER_NUMBER> and <adjacent member number>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fabric blade is showed to have a faulty link to a Slot in the chassis. Error may be recoveralbe, but if persistant the Fabric needs field replacement.

Event ID: 932 (Severity: Warning)

Message
chassis: Unknown fabric failure: link between Fabric <MEMBER_NUMBER> and <adjacent member number> down
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when the link between a fabric blade and a Slot has an error that can't be traced to either the fabric or the Slot without further testing.

Event ID: 933

Message
Chassis running at reduced backplane capacity
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when we're operating with fewer active fabrics than required to maintain the backplane's full capacity.

Event ID: 934 (Severity: Warning)

Message
Chassis has no active fabrics. Line cards resetting.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when there are no active fabric modules. (They are either not present, failed, or disabled.)

Event ID: 935

Message
Fabric <MEMBER_NUMBER> disabled via configuration setting
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when a fabric blade is disabled via configuration setting.

Event ID: 936

Message
Fabric <MEMBER_NUMBER> enabled
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when a fabric blade is enabled via configuration setting.

Event ID: 937

Message
Fabric <MEMBER_NUMBER> inserted
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when a fabric blade is inserted (or first detected at boot time)

Event ID: 938 (Severity: Warning)

Message
Fabric failure: Fabric <MEMBER_NUMBER> not responding
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fabric blade won't respond on the SRI.

Event ID: 939 (Severity: Warning)

Message
Fabric failure: Fabric <MEMBER_NUMBER> failed selftest
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fabric blade fails selftest.

Event ID: 940 (Severity: Warning)

Message
Fabric failure: Fabric <MEMBER_NUMBER> power failure
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fabric blade's power supply fails.

Event ID: 941 (Severity: Fatal)

Message
<WHERE_INTERRUPT_OCCURRED> Fatal <WHICH_INTERRUPT_OCCURRED> F<which fabric the interrupt occurred on>: <HSL/NCI/ICL> Slot: <slot or port number> Status: <register value associated with the interrupt>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description HSL/NCI fatal interrupts from fabric

Event ID: 942 (Severity: Warning)

Message
<WHERE_INTERRUPT_OCCURRED> Non-Fatal <WHICH_INTERRUPT_OCCURRED> F<which fabric the interrupt occurred on>: <HSL/NCI/ICL> Slot: <slot or port number> Status: <register value associated with the interrupt>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description HSL/NCI non-fatal interrupts from fabric

Event ID: 2550

Message
Requesting Co-processor OS image location in flash.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager requests the slave OS image from the download task.

Event ID: 2551 (Severity: Fatal)

Message
Failed to obtain Co-processor OS image location.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when the download task is unable to provide the slave OS image location.

Event ID: 2552

Message
Loading of Co-processor OS image in progress.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager is getting the slave OS from flash, decompressing, and copying the OS into the slave area of RAM.

Event ID: 2553

Message
Loading of Co-processor OS image complete.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager has completed copying the slave OS into the slave area of RAM.

Event ID: 2554 (Severity: Fatal)

Message
Failed loading the Co-processor OS image.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when chassis manager has failed to copy the slave OS into the slave area of RAM.

Event ID: 2555

Message
Co-processor Ready
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever the slave core (Samba) goes into the state of Available.

Event ID: 2556

Message
Stack port <PORT_NUMBER> cable inserted.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a stack cable is inserted, in an operational chassis.

Event ID: 2557

Message
Stack port <PORT_NUMBER> cable removed.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a stack cable is removed, from an operational chassis.

Event ID: 2558

Message
Stack port <PORT_NUMBER> cable is on-line.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a stack port completes initialization, in an operational chassis.

Event ID: 2559

Message
Stack port <PORT_NUMBER> cable is off-line.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a stack port is disabled or goes off-line, in an operational chassis.

Event ID: 2560 (Severity: Warning)

Message
Stack port <PORT_NUMBER> cable initialization error.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays whenever a stack port fails for some reason, in an operational chassis.

Event ID: 2561 (Severity: Warning)

Message
chassis: <MODULE> is not a supported Switch module. Please go to: http://www.arubanetworks.com/products/networking/ for more info.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an expansion module fails HPIDv2 authentication

Event ID: 2563 (Severity: Warning)

Message
chassis: PoE controller X Reset.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when PoE contrller has been reset.

Event ID: 2564 (Severity: Warning)

Message
PoE pre-std-detect mode is enabled. Power may be applied to non-PDs. Use only with legacy devices. To disable power on specific ports- use "no interface <PORT_LIST> power".
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when PoE pre standard detect is enabled.

Event ID: 2565 (Severity: Warning)

Message
50V Power Supply <PORT_NUMBER> AC Glitch. Glitches: <port state>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an IPS AC is interrupted but DC remains Ok.

Event ID: 2568

Message
<STATE_RECORD> Core Dump Uploading
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager begins uploading a core dump from a new card.

Event ID: 2569

Message
<STATE_RECORD> Core Dump Upload Complete
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when chassis manager finishes uploading the core dump from a new card.

Event ID: 2570 (Severity: Warning)

Message
<STATE_RECORD> Core Dump Upload Failed
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays if chassis manager fails to upload the core dump from a new card.

Event ID: 2750

Message
LEDs for module in slot <SLOT_NAME> configured OFF.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a module's LED's are configured to be off in savepower mode, in an operational chassis.

Event ID: 2751

Message
LEDs for module in slot <SLOT_NAME> configured ON.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a module's LED's are configured to be on in normal mode, in an operational chassis.

Event ID: 2752

Message
Ports on module in <SLOT_NAME> configured to low power mode.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a module's PHY are configured to Auto low power mode, in an operational chassis.

Event ID: 2753

Message
Ports on module in <SLOT_NAME> configured to normal power mode.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a module's PHY are configured to normal power mode, in an operational chassis.

Event ID: 2754

Message
Request for \"savepower module <SLOT_LIST>\".
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a slot is being powered down, in an operational chassis.

Event ID: 2755

Message
Slot <SLOT_NAME> is powered down.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a slot is being powered down, in an operational chassis.

Event ID: 2756

Message
Slot <SLOT_NAME> is powered up.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a slot is powered up, from the savepower mode, in an operational chassis.

Event ID: 2757

Message
Savepower LED timer is ACTIVE.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever the timer for LED powersave feature becomes active, in an operational chassis.

Event ID: 2758

Message
Savepower LED timer is SCHEDULED.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever the timer for LED powersave feature is scheduled, in an operational chassis.

Event ID: 2759

Message
Savepower LED timer is OFF.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever the timer for LED powersave feature expires or is cancelled, in an operational chassis.

Event ID: 2762

Message
Request for \reload module <SLOT_LIST>\".
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays whenever a slot is reloaded, in an operational chassis.

Event ID: 2763

Message
Configuration removed for module in slot <SLOT_NAME>.
Platforms KB
Category Chassis
Severity Information
Description This message displays when a slot has been removed with the 'no module' command and the entire configuration for the module has been deleted.

Event ID: 2765 (Severity: Warning)

Message
Unsupported mixed power supply types (PoE & PoE+) detected in chassis.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when mixed power supplies are present in the chassis (including RailHead)

Event ID: 2766

Message
Supported same power supply types (PoE or PoE+) restored in chassis.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when single type (POE or POE+) power supplies are present in the chassis (including RailHead)

Event ID: 2769 (Severity: Warning)

Message
<SLOT_NAME> Ext Power Supply <GROUP_INDEX> measured out of spec or is faulty. Please change or contact support.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an EPS is plugged in and SW reads invalid isrc value

Event ID: 2777 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER> communication <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count:
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply has an internal communications error that results in running the PSU fans at max.

Event ID: 2778 (Severity: Warning)

Message
Internal power supply <BAY_NUMBER>: Fan <FAN_NUM_FAULTED | FAN_NUM_OK>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fan on an internal power supply has failed. Power supply will still provide power and has not shut down.

Event ID: 2779 (Severity: Warning)

Message
Internal power supply <BAY_NUMBER>: Output power <EXCEEDS | WITHIN> the threshold value.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a power supply's power output has exceeded a threshold. Power supply will still provide power and has not shut down.

Event ID: 2780 (Severity: Warning)

Message
Internal power supply <BAY_NUMBER>: System current<EXCEEDS | WITHIN> the threshold value.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a power supply's system current has exceeded a threshold. Power supply will still provide power and has not shut down.

Event ID: 2781 (Severity: Warning)

Message
Internal power supply <BAY_NUMBER>: PoE current <EXCEEDS | WITHIN> the threshold value.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a power supply's POE current has exceeded a threshold. Power supply will still provide power and has not shut down.

Event ID: 2782 (Severity: Warning)

Message
Internal power supply <BAY_NUMBER>: Auxiliary inlet power is <FAN_NUM_FAULTED | FAN_NUM_OK>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a power supply's auxiliary power inlet has lost power. Power supply will still provide power and has not shut down.

Event ID: 2783 (Severity: Warning)

Message
Internal power supply <BAY_NUMBER>: System power temperature <EXCEEDS | WITHIN> the threshold value.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a power supply's system power rail's temperature has exceeded a threshold. Power supply will still provide power and has not shut down.

Event ID: 2784 (Severity: Warning)

Message
Internal power supply <BAY_NUMBER>: PoE power temperature <EXCEEDS | WITHIN> the threshold value.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a power supply's system power rail's temperature has exceeded a threshold. Power supply will still provide power and has not shut down.

Event ID: 2785 (Severity: Warning)

Message
Internal power supply <BAY_NUMBER>: Inlet air temperature <EXCEEDS | WITHIN> the threshold value.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a power supply's inlet air temperature has exceeded a threshold. Power supply will still provide power and has not shut down.

Event ID: 2786 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: Power usage <EXCEEDS | WITHIN> the threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's output power has exceeded a threshold. Power supply has shut down.

Event ID: 2787 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: System <EXCEEDS | WITHIN> the current threshold value. Power supply<FAN_NUM_FAULTED | FAN_NUM_OK> Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's system power's current has exceeded a threshold. Power supply has shut down.

Event ID: 2788 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: System <EXCEEDS | WITHIN> the voltage threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's system power's voltage has exceeded a threshold. Power supply has shut down.

Event ID: 2789 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: Auxiliary PoE <EXCEEDS | WITHIN> the current threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's auxiliary POE power has exceeded its current threshold. Power supply has shut down.

Event ID: 2790 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: Auxiliary PoE <EXCEEDS | WITHIN> the voltage threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's auxiliary POE power has exceeded its voltage threshold. Power supply has shut down.

Event ID: 2791 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: Main PoE <EXCEEDS | WITHIN> the current threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's main POE power has exceeded its current threshold. Power supply has shut down.

Event ID: 2792 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: Main PoE <EXCEEDS | WITHIN> the voltage threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's main POE power has exceeded its voltage threshold. Power supply has shut down.

Event ID: 2793 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: Main inlet <EXCEEDS | WITHIN>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's main power inlet has lost power. Power supply has shut down.

Event ID: 2794 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: PoE power <EXCEEDS | WITHIN> the temperature threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's POE power's temperature is too high. Power supply has shut down.

Event ID: 2795 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER>: System power <EXCEEDS | WITHIN> the temperature threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's POE power's temperature is too high. Power supply has shut down.

Event ID: 2796 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER> <'inserted' or 'removed'>. Total fault count: <number of failures>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply has been removed.

Event ID: 2797 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER> is <'ok' or 'faulted'>. Total fault count: <number of failures>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply has lost all power.

Event ID: 2798 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER> main PoE power <'ok' or 'faulted'>. Total fault count: <number of failures>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's main POE source has lost power.

Event ID: 2799 (Severity: Fatal)

Message
Internal power supply <BAY_NUMBER> auxiliary PoE power <'ok' or 'faulted'>. Total fault count: <number of failures>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when a power supply's auxiliary POE source has lost power.

Event ID: 3360 (Severity: Fatal)

Message
Interface Module image id <slave image id> corrupted.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays if the slave image loaded during chassis bootup is corrupted. It could be the source corrupted or during the copy process to memory

Event ID: 3802

Message
System Self test started on <'STAND_ALONE' OR 'MASTER'>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description The reason why the management alone' has system self test started.

Event ID: 3803

Message
System Self test completed on <'STAND_ALONE' OR 'MASTER'>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description The reason why the management alone' has system self test completed.

Event ID: 3804

Message
System Self test failed on <'STAND_ALONE' OR 'MASTER'>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description The reason why the management alone' has system self test failed.

Event ID: 3831 (Severity: Warning)

Message
EEE cannot be enabled on <SLOT_NAME> on this hardware revision.
Platforms KB, WB, WC, YA, YC
Category Chassis
Severity Warning
Description This message will appear when a slot that has EEE HW issue gets a EEE enable request from config.

Event ID: 3832 (Severity: Warning)

Message
<SLOT_NAME> Invalid: Module not supported in this quantity and/or slot configuration
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message will appear when module in indicated slot violates a quantity and/or slot-configuration restriction.

Event ID: 3833 (Severity: Warning)

Message
<SLOT_NAME> Invalid: The module is not supported in this chassis.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message will appear when a version 1 zl blade is inserted into a Bolt/Rhino chassis.

Event ID: 3834 (Severity: Warning)

Message
Power Supply <POWER_INDEX> <'inserted'>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description PSU/IPS insert info log msg.

Event ID: 3835 (Severity: Warning)

Message
Power Supply <POWER_INDEX> removed while <'powered' or 'not powered'>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description PSU/IPS remove info log msg.

Event ID: 3836 (Severity: Fatal)

Message
<WHERE_INTERRUPT_OCCURRED> Fatal <WHICH_INTERRUPT_OCCURRED> <WHICH_FABRIC_INTERRUPT_OCCURRED_ON>: <HSL/NCI/ICL> StackPort: <SLOT_OR_PORT_NUMBER> Status: <REGISTER_VALUE_ASSOCIATED_WITH_INTERRUPT> <SECONDARY_REGISTER_VALUE_ASSOCIATED_WITH_INTERRUPT>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description HSL/NCI fatal interrupts from fabric on stacking devices.

Event ID: 3837 (Severity: Warning)

Message
<WHERE_INTERRUPT_OCCURRED> Non-Fatal <WHICH_INTERRUPT_OCCURRED> <WHICH_FABRIC_INTERRUPT_OCCURRED_ON>: <HSL/NCI/ICL> StackPort: <SLOT_OR_PORT_NUMBER> Status: <REGISTER_VALUE_ASSOCIATED_WITH_INTERRUPT> <SECONDARY_REGISTER_VALUE_ASSOCIATED_WITH_INTERRUPT>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description HSL/NCI non-fatal interrupts from fabric on stacking devs.

Event ID: 3838 (Severity: Warning)

Message
<SLOT_PORT> failed to boot. Timeout reached: <SOURCE>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description The reason why the management port has boot timeout reached source.

Event ID: 3839 (Severity: Warning)

Message
<SLOT_NAME>: Lost Communications detected - <LOST_COMM_SOURCE> (<DLL_VALUE>2X)
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description module/coproc communications lost

Event ID: 3840 (Severity: Warning)

Message
<name> module ROM Tomstone: <TOMBSTONE>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description The reason why the management module has tombstone.

Event ID: 4050

Message
External power supply power-share request is completed.
Platforms WB
Category Chassis
Severity Information
Description Message displays when user change allocated power for PPS

Event ID: 4051 (Severity: Warning)

Message
Unable to perform power-share as requested. Reason: <reason for failing>.
Platforms WB
Category Chassis
Severity Warning
Description Message displays when user's power allocation request could not be serviced

Event ID: 4052

Message
External power supply connection status changed from <pps state> to <local cable status>.
Platforms WB
Category Chassis
Severity Information
Description Message displays when status of PPS changed

Event ID: 4053

Message
External power supply has been restored to factory default.
Platforms WB
Category Chassis
Severity Information
Description Message displays when PPS has been restored to factory default

Event ID: 4054 (Severity: Warning)

Message
There is a mismatch in power supply ratings between external power supply and this switch. External power supply configurations not allowed.
Platforms WB
Category Chassis
Severity Warning
Description Message displays when status of PPS PSU mismatch

Event ID: 4055 (Severity: Warning)

Message
12v standby rail on external power supply has failed.
Platforms WB
Category Chassis
Severity Warning
Description Message displays when 12v standby rail is bad

Event ID: 4056

Message
External power supply power allocated has changed to <power per cable> watts by <pps over temp zone>.
Platforms WB
Category Chassis
Severity Information
Description Message displays when a xps POE power change is detected

Event ID: 4057 (Severity: Warning)

Message
Over current has been detected on external power supply. <log>
Platforms WB
Category Chassis
Severity Warning
Description Message displays when PPS encountered over current

Event ID: 4058 (Severity: Warning)

Message
Over temperature has been detected on external power supply.
Platforms WB
Category Chassis
Severity Warning
Description Message displays when PPS encountered over temperature

Event ID: 4059 (Severity: Warning)

Message
Main power rail on external power supply has failed.
Platforms WB
Category Chassis
Severity Warning
Description Message displays when main rail is bad

Event ID: 4060 (Severity: Warning)

Message
External power supply error: <specific error message>
Platforms WB
Category Chassis
Severity Warning
Description log message for generic xps error.

Event ID: 4061

Message
External power supply ready.
Platforms WB
Category Chassis
Severity Information
Description Message displays when PPS is ready

Event ID: 4062 (Severity: Warning)

Message
Unsupported power supply configurations detected on external power supply.<EVENT_MSG>
Platforms WB
Category Chassis
Severity Warning
Description Message displays when PPS has an unsupported PSU inserted

Event ID: 4063

Message
External power supply port is now in <'enabled' or 'disabled'> state.
Platforms WB
Category Chassis
Severity Information
Description Message displays when HSC on PPS is not turned on

Event ID: 4064 (Severity: Warning)

Message
Unable to restore external power supply to factory default as requested. Reason: <EVENT_MSG>
Platforms WB
Category Chassis
Severity Warning
Description Message displays when PPS cannot be restored to factory default.

Event ID: 4065

Message
External power supply zone record status: <EVENT_MSG>
Platforms WB
Category Chassis
Severity Information
Description Message displays when mailbox has been locked by another system

Event ID: 4066

Message
External power supply power reduction completed.
Platforms WB
Category Chassis
Severity Information
Description Message displays when low priority power reduction is successful

Event ID: 4067 (Severity: Warning)

Message
Unable to reduce external power supply power as requested. Reason: <EVENT_MSG>.
Platforms WB
Category Chassis
Severity Warning
Description Message displays when low priority power reduction failed

Event ID: 4068 (Severity: Warning)

Message
Unable to control external power supply port <LOCAL_ZONE_OR_LOCAL_CABLE> as requested. Reason: <EVENT_MSG>.
Platforms WB
Category Chassis
Severity Warning
Description Message displays when HSC control cmd failed

Event ID: 4069

Message
External power supply info: <EVENT_MSG>
Platforms WB
Category Chassis
Severity Information
Description Message displays XPS info log msg.

Event ID: 4070 (Severity: Warning)

Message
SD card self-test fail. Error code: <SD_CARD_RESULTS>. Reformat SD card from BootROM CLI.
Platforms KB, WB, WC, YC
Category Chassis
Severity Warning
Description The reason why the management card has fail error code sd card results reformat sd card from bootrom cli.

Event ID: 4697 (Severity: Warning)

Message
Fabric failure: Link error between Member <STACK_MEMBER_NUMBER> Stack port <PORT_NUMBER> and Member <STACK_MEMBER_NUMBER> Stack port <PORT_NUMBER>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fabric error is detected on the stacking link that connects this member to another member in a backplane stack. Error may be recoverable, but if persistent the stacking cable, stacking module or chassis needs field replacement.

Event ID: 4698 (Severity: Warning)

Message
Fabric failure: Uncategorized link error between Member <STACK_MEMBER_NUMBER> Stack port <PORT_NUMBER> and Member <STACK_MEMBER_NUMBER> Stack port <PORT_NUMBER>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a fabric error is detected on the stacking link that connects this member to another member in a backplane stack. Error may be recoverable, but if persistent the stacking cable, stacking module or chassis needs field replacement.

Event ID: 4701 (Severity: Fatal)

Message
<SLOT_NAME>: fatal software error
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description The reason why the management has device slot crash message.

Event ID: 4702 (Severity: Fatal)

Message
<SLOT_NAME>: fatal software error
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description The reason why the management has device fixed slot crash message.

Event ID: 5043 (Severity: Warning)

Message
Member <1-10>: Flexible Module <J_NUMBER> in slot <A or B> is inactive. Flexible Module <J_NUMBER> does not match configured <J_NUMBER>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an inserted expansion module is different than what has been provisioned for the slot in a stacking context.

Event ID: 5044 (Severity: Warning)

Message
Flexible Module <J_NUMBER> in slot <A or B> is inactive. Flexible Module <J_NUMBER> does not match configured <J_NUMBER>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when an inserted expansion module is different than what has been provisioned for the slot in a standalone context.

Event ID: 5045

Message
Member <1-10>: Flexible Module <J_NUMBER> inserted in slot <A or B>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an expansion module is inserted in a stacked switch.

Event ID: 5046

Message
Flexible Module <J_NUMBER> inserted in slot <A or B>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an expansion module is inserted in a standalone switch.

Event ID: 5047

Message
Member <1-10>: flexible module <J_NUMBER> in slot <A or B> is active.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an inserted expansion module is powered up or inserted and becomes active in a stack.

Event ID: 5048

Message
Flexible Module <J_NUMBER> in slot <A or B> is active.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an inserted expansion module is powered up or inserted and becomes active in a standalone switch.

Event ID: 5049

Message
Member <1-10>: Flexible module <J_NUMBER> removed from slot <A or B>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an expansion module is unprovisioned in a stack.

Event ID: 5050

Message
Flexible module <J_NUMBER> removed from slot <A or B>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an expansion module is unprovisioned in a standalone switch.

Event ID: 5053

Message
Member <1-10>: Savepower mode is enabled on <Flexible module A|B>. Flexible Module <J_NUMBER> in slot <A or B> is powered down.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an expansion module is powered down in a stack.

Event ID: 5054

Message
Savepower mode is enabled on <Flexible module A|B>. Flexible Module <J_NUMBER> in slot <A or B> is powered down.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an expansion module is powered down in a standalone config.

Event ID: 5055

Message
Member <1-10>: Savepower mode is disabled on <Flexible module A|B>. Flexible Module <J_NUMBER> in slot <A or B> is powered up.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an expansion module is powered up in a stack.

Event ID: 5056

Message
Savepower mode is disabled on <Flexible module A|B>. Flexible Module <J_NUMBER> in slot <A or B> is powered up.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when an expansion module is powered up in a standalone config.

Event ID: 5083

Message
Ports X-Y: PoE Software updated from version A to B.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when PoE controller firmware is updated successfully

Event ID: 5084

Message
Ports X-Y: PoE Software update failed with error code A. Contact support for assistance.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description This message displays when PoE controller firmware update process fails.

Event ID: 5173 (Severity: Fatal)

Message
System power failure
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Fatal
Description This message displays when Domain Power faults.

Event ID: 5174 (Severity: Warning)

Message
System power recovered. Resetting system to restore operation
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays on a transition to Good Domain Power.

Event ID: 5263

Message
Power fault detected on <MODULE>.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description Message will appear when a power fault is detected on an Expansion Module.

Event ID: 5356 (Severity: Warning)

Message
MAC-level transmit error on port <PORT_ID>. If this reoccurs frequently- contact Technical Support.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description Too many MAC interrupts were received on a port.

Event ID: 5570 (Severity: Warning)

Message
5V power supply failure. <ADDITIONAL INFO>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a permanent 5V DC power fault occurs with additional information. Software is not able to restore 5V DC power.

Event ID: 5571 (Severity: Warning)

Message
Power fault on USB port.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a 5V DC power supply fault occurs that is cleared by disabling the USB port. Causes for this fault include a faulty USB device or a fault in the USB port itself.

Event ID: 5572 (Severity: Warning)

Message
Overcurrent detected on USB port.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description This message displays when a USB over current fault occurs. This typically occurs when a faulty USB device has been installed.

Event ID: 5573

Message
Normal operation restored on USB port.
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Information
Description A USB over current condition has been resolved and normal operation has been restored on the USB port.

Event ID: 5822 (Severity: Warning)

Message
Over Temperature: Transceiver in port <PORT_NAME_STR>
Platforms KB, WB, WC, YA, YB, YC
Category Chassis
Severity Warning
Description Indicates that the temperature detected is high on a transceiver port.

Event ID: 5901 (Severity: Warning)

Message
Stack port <STACK_PORT_NUM> phy link error, please check the stacking cable.
Platforms WB, WC
Category Chassis
Severity Warning
Description Indicates stacking cable failures.

Event ID: 5904 (Severity: Warning)

Message
Over Temperature: ports <port range>
Platforms KB, WC, YC
Category Chassis
Severity Warning
Description This message will appear when there is an over temperature detected on the mentioned ports. If the over temperature persists, the log will be repeated every 60 minutes.

Event ID: 5905 (Severity: Warning)

Message
Over Temperature: slot <slot name>
Platforms KB
Category Chassis
Severity Warning
Description This message will appear when there is an over temperature detected on the mentioned slot in a modular switch. If the over temperature persists, the log will be repeated every 60 minutes.