User Tunneled Node Events

The following are the events related to user tunneled node.

Event ID: 5401

Message
Server <IP_ADDR> is <PORT_CAPABILITY> capable.
Platforms KB, WC
Category User Tunneled Node
Severity Information
Description Capability of a Aruba Mobility Controller is logged. This log mentions whether the given Controller is Per Port or Per User Capable. Server <Controller Ip> is <Per Port| Per User> capable.

Event ID: 5402

Message
Switch Anchor Controller (SAC) is <IP_ADDR>.
Platforms KB, WC
Category User Tunneled Node
Severity Information
Description Primary Switch Anchor Controller's(A-SAC's) IP is logged. This log provides the IP of Primary SAC Switch Anchor Controller (SAC) is <Controller Ip>.

Event ID: 5403

Message
Standby Switch Anchor Controller is <IP_ADDR>.
Platforms KB, WC
Category User Tunneled Node
Severity Information
Description Secondary Switch Anchor Controller's(S-SAC's) IP is logged. This log provides the IP of Secondary SAC Standby Switch Anchor Controller is <Controller Ip>.

Event ID: 5404

Message
<EVENT_NAME> event received from Switch Anchor Controller (SAC) <IP_ADDR>.
Platforms KB, WC
Category User Tunneled Node
Severity Information
Description Event received from SAC is logged. <Event Name> event received from Switch Anchor Controller (SAC) <SAC Ip>

Event ID: 5405

Message
Anchor controller <IP_ADDR> is down.
Platforms KB, WC
Category User Tunneled Node
Severity Information
Description This log notifies that the primary controller is down. Anchor controller <Controller Ip> is down

Event ID: 5406

Message
Port <PORT_NAME>: tunnel established to User Anchor Controller (UAC) <IP_ADDR> for user <CLIENT_MAC_ADDR>.
Platforms KB, WC
Category User Tunneled Node
Severity Information
Description This log notifies that a tunnel has been established from a particular port to a given UAC for the specific user.

Event ID: 5407

Message
Tunneling user <CLIENT_MAC_ADDR> traffic to User Anchor Controller (UAC) <IP_ADDR> failed due to reason: <REASON_MSG>.
Platforms KB, WC
Category User Tunneled Node
Severity Information
Description This log notifies that tunneling for a particular User failed due to given reason.

Event ID: 5408

Message
Communication failure with Anchor Controller <IP_ADDR> due to reason: <REASON_MSG>.
Platforms KB, WC
Category User Tunneled Node
Severity Information
Description This log notifies that communication with a Controller failed with given reason code.

Event ID: 5409 (Severity: Warning)

Message
Misconfiguration detected for user <USER_NAME>: uplink port <PORT_ID> is member of client VLAN <VLAN_ID>; User traffic will not be tunneled
Platforms KB, WC
Category User Tunneled Node
Severity Warning
Description This logs VLAN misconfiguration. uplink port is part of the client VLAN.

Event ID: 5410 (Severity: Warning)

Message
Controller version <FIRMWARE_VERSION> does not support vlan-extension disable. Suggest enabling vlan-extension or upgrading the controller.
Platforms KB, WC
Category User Tunneled Node
Severity Warning
Description Incompatible firmware version of controller is used with no-vlan mode enabled on the switch.

Event ID: 5411 (Severity: Warning)

Message
Failed to apply user role <USER_ROLE_NAME> to <CLIENT_MAC> client <CLIENT_MODE> on port <PORT_NAME>: vlan-extend is enabled but user-role does not have a vlan-id.
Platforms KB, WC
Category User Tunneled Node
Severity Warning
Description Occurs when a user-role, which has tunneled-node-server-redirect attribute set without configuring vlan-id(tagged/untagged) is used and vlan-mode is vlan-extend-enable.

Event ID: 5412 (Severity: Warning)

Message
Cannot downgrade to <FLASH_IMAGE_VERSION> version as the user role <USER_ROLE_NAME> has no vlan configured.
Platforms KB, WC
Category User Tunneled Node
Severity Warning
Description Switch downgrade to 16.06 or below when vlan-mode is vlan-extend-enable and redirect attribute is set without configuring vlan-id in user-role.

Event ID: 5413 (Severity: Warning)

Message
Cannot downgrade to <FLASH_IMAGE_VERSION> version as the tunneled-node-server is operating in vlan-extenddisable mode.
Platforms KB, WC
Category User Tunneled Node
Severity Warning
Description Cannot downgrade to <FLASH_IMAGE_VERSION> version as the tunneled-node-server is operating in vlan-extend disable mode.

Event ID: 5414 (Severity: Warning)

Message
Firmware downgrade is not allowed when Primary or Backup Controller is configured with IPv6 address. Please delete Primary or Backup Controller with IPv6 address manually to continue the downgrade.
Platforms KB, WC
Category User Tunneled Node
Severity Warning
Description Cannot downgrade to 16.07 or lower version if ipv6 address is configured for controller or backup-controller.

Event ID: 5415 (Severity: Warning)

Message
Uplink VLAN <VLAN_ID> MTU administratively changed from old <OLD_MTU> to new <NEW_MTU> and needs to be communicated to controller. Please re-enable tunneled-node-server for graceful MTU update..
Platforms KB, WC
Category User Tunneled Node
Severity Warning
Description Uplink VLAN 192 MTU administratively changed from old (1501) to new (1500) and must be communicated to controller. Re-enable tunneled-node-server for graceful MTU update.

Event ID: 5451

Message
<DST_IP> reachable via vlan <VLAN_ID> (<GATEWAY_IP>)
Platforms KB, WC
Category User Tunneled Node
Severity Debug