User Tunneled Node Events
The following are the events related to user tunneled node.
Event ID: 5401
Message | Server <IP_ADDR> is <PORT_CAPABILITY> capable. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Information |
Description | Capability of a Aruba Mobility Controller is logged. This log mentions whether the given Controller is Per Port or Per User Capable. Server <Controller Ip> is <Per Port| Per User> capable. |
Event ID: 5402
Message | Switch Anchor Controller (SAC) is <IP_ADDR>. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Information |
Description | Primary Switch Anchor Controller's(A-SAC's) IP is logged. This log provides the IP of Primary SAC Switch Anchor Controller (SAC) is <Controller Ip>. |
Event ID: 5403
Message | Standby Switch Anchor Controller is <IP_ADDR>. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Information |
Description | Secondary Switch Anchor Controller's(S-SAC's) IP is logged. This log provides the IP of Secondary SAC Standby Switch Anchor Controller is <Controller Ip>. |
Event ID: 5404
Message | <EVENT_NAME> event received from Switch Anchor Controller (SAC) <IP_ADDR>. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Information |
Description | Event received from SAC is logged. <Event Name> event received from Switch Anchor Controller (SAC) <SAC Ip> |
Event ID: 5405
Message | Anchor controller <IP_ADDR> is down. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Information |
Description | This log notifies that the primary controller is down. Anchor controller <Controller Ip> is down |
Event ID: 5406
Message | Port <PORT_NAME>: tunnel established to User Anchor Controller (UAC) <IP_ADDR> for user <CLIENT_MAC_ADDR>. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Information |
Description | This log notifies that a tunnel has been established from a particular port to a given UAC for the specific user. |
Event ID: 5407
Message | Tunneling user <CLIENT_MAC_ADDR> traffic to User Anchor Controller (UAC) <IP_ADDR> failed due to reason: <REASON_MSG>. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Information |
Description | This log notifies that tunneling for a particular User failed due to given reason. |
Event ID: 5408
Message | Communication failure with Anchor Controller <IP_ADDR> due to reason: <REASON_MSG>. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Information |
Description | This log notifies that communication with a Controller failed with given reason code. |
Event ID: 5409 (Severity: Warning)
Message | Misconfiguration detected for user <USER_NAME>: uplink port <PORT_ID> is member of client VLAN <VLAN_ID>; User traffic will not be tunneled |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Warning |
Description | This logs VLAN misconfiguration. uplink port is part of the client VLAN. |
Event ID: 5410 (Severity: Warning)
Message | Controller version <FIRMWARE_VERSION> does not support vlan-extension disable. Suggest enabling vlan-extension or upgrading the controller. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Warning |
Description | Incompatible firmware version of controller is used with no-vlan mode enabled on the switch. |
Event ID: 5411 (Severity: Warning)
Message | Failed to apply user role <USER_ROLE_NAME> to <CLIENT_MAC> client <CLIENT_MODE> on port <PORT_NAME>: vlan-extend is enabled but user-role does not have a vlan-id. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Warning |
Description | Occurs when a user-role, which has tunneled-node-server-redirect attribute set without configuring vlan-id(tagged/untagged) is used and vlan-mode is vlan-extend-enable. |
Event ID: 5412 (Severity: Warning)
Message | Cannot downgrade to <FLASH_IMAGE_VERSION> version as the user role <USER_ROLE_NAME> has no vlan configured. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Warning |
Description | Switch downgrade to 16.06 or below when vlan-mode is vlan-extend-enable and redirect attribute is set without configuring vlan-id in user-role. |
Event ID: 5413 (Severity: Warning)
Message | Cannot downgrade to <FLASH_IMAGE_VERSION> version as the tunneled-node-server is operating in vlan-extenddisable mode. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Warning |
Description | Cannot downgrade to <FLASH_IMAGE_VERSION> version as the tunneled-node-server is operating in vlan-extend disable mode. |
Event ID: 5414 (Severity: Warning)
Message | Firmware downgrade is not allowed when Primary or Backup Controller is configured with IPv6 address. Please delete Primary or Backup Controller with IPv6 address manually to continue the downgrade. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Warning |
Description | Cannot downgrade to 16.07 or lower version if ipv6 address is configured for controller or backup-controller. |
Event ID: 5415 (Severity: Warning)
Message | Uplink VLAN <VLAN_ID> MTU administratively changed from old <OLD_MTU> to new <NEW_MTU> and needs to be communicated to controller. Please re-enable tunneled-node-server for graceful MTU update.. |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Warning |
Description | Uplink VLAN 192 MTU administratively changed from old (1501) to new (1500) and must be communicated to controller. Re-enable tunneled-node-server for graceful MTU update. |
Event ID: 5451
Message | <DST_IP> reachable via vlan <VLAN_ID> (<GATEWAY_IP>) |
Platforms | KB, WC |
Category | User Tunneled Node |
Severity | Debug |