Chassis Events
The following are the events related to Chassis.
Event ID: 67
Message | chassis: <SLOT_NAME> Removed |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a card in a slot is removed from an operational switch chassis. The <SLOT_NAME> in the format will indicate the slot from which the card was removed. |
Event ID: 68
Message | chassis: <SLOT_NAME> Inserted |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a card is inserted into a slot in an operational system. |
Event ID: 69 (Severity: Fatal)
Message | chassis: <SLOT_NAME> Hotswap Failure |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays whenever a slot in a switch chassis fails hotswap. The <SLOT_NAME> in the message will indicate the failed slot. |
Event ID: 70 (Severity: Warning)
Message | Fan <STATUS_OK_OR_FAILURE>: Fan: <ID> Failures: <NUM_FAILURES> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the software notices that a fan has failed or when a failed fan is no longer failing. The fan state is indicated as {failure | OK}. The fan is indicated as fan 1 or fan 2. The number of times the fan has failed will also be indicated. The fan fail LED will also be lit. |
Event ID: 71 (Severity: Warning)
Message | Power Supply <STATUS_OK_OR_FAILURE>: Supply: <ID>- Failures: <NUM_FAILURES> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the software notices that the RPS is failing or the RPS is present and the main power supply is failing or when a failed supply is no longer failing. The supply state will be indicated as {failure | OK}. The supply will be indicated as {Main | RPS}. The message will also indicate the number of times the supply has failed. The power fail LED will also be lit. |
Event ID: 72 (Severity: Warning)
Message | chassis: <SLOT_NAME> Inactive: Module/Configuration mismatch |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a module has been inserted that is incompatable with the previous module in the indicated slot. |
Event ID: 73 (Severity: Fatal)
Message | Chassis Backplane Power Fault: Chassis needs replacement. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Event ID: 274 (Severity: Warning)
Message | chassis: <SLOT_NAME> self test failure or unsupported module |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the indicated slot has failed selftest completely or when there are no usable ports on the slot. |
Event ID: 278
Message | Module in slot <SLOT_NAME> not allowed |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | Re-enable the port since the BPDU protection auto-enable timer has expired. |
Event ID: 371 (Severity: Warning)
Message | Port <PORT-NAME> self test failure ERR: <failure code> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the indicated port has failed selftest and is unusable. |
Event ID: 372 (Severity: Warning)
Message | Invalid transceiver installed in Port <PORT-NAME> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the indicated port has an invalid transceiver installed. |
Event ID: 373 (Severity: Warning)
Message | Boot ROM self test failure! |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the indicated port has an invalid transceiver installed. |
Event ID: 374 (Severity: Warning)
Message | chassis: Lost Communication with <SLOT_NAME> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when Chassis Mgr. fails to receive a heartbeat response from a particular slave card. |
Event ID: 375
Message | chassis: <SLOT_NAME> Downloading |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager begins downloading a new card. |
Event ID: 376
Message | chassis: <SLOT_NAME> Download Complete |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager finishes downloading a new card. |
Event ID: 377 (Severity: Warning)
Message | chassis: <SLOT_NAME> Download Failed |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays if chassis manager fails to download a new card. |
Event ID: 422
Message | chassis: <SLOT_NAME> Available |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a slave card (ALpha/Gamma/Delta) goes into the state |
Event ID: 423 (Severity: Warning)
Message | chassis: Unable to Download to <SLOT_NAME>. Please Remove Module |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays whenever a slave card has exceeded the number of download |
Event ID: 424 (Severity: Warning)
Message | chassis: Module in <SLOT_NAME> not Supported or may be Faulty |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays whenever the master does not receive a download request from |
Event ID: 425 (Severity: Warning)
Message | chassis: Backplane link to <SLOT_NAME> failed self test |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays whenever the master does not receive a download request from |
Event ID: 549 (Severity: Warning)
Message | Insufficient power supplies to power <SLOT_NAME> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Event ID: 550
Message | Module Inserted |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager sees the module inserted. |
Event ID: 551 (Severity: Warning)
Message | <SLOT_NAME> Module failed self test |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when chassis manager sees the module inserted. |
Event ID: 552 (Severity: Warning)
Message | <Stacking Module> insertion detected: Reboot required |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when chassis manager sees the module inserted. |
Event ID: 553 (Severity: Warning)
Message | Over-temperature detected. Failures: <MODULE_NUMBER> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the software notices that the RPS is failing or the RPS is present and the main power supply is failing or when a failed supply is no longer failing. The supply state will be indicated as {failure | OK}. The supply will be indicated as {Main | RPS}. The message will also indicate the number of times the supply has failed. The power fail LED will also be lit. |
Event ID: 554 (Severity: Warning)
Message | <SLOT_NAME> NCI error IntReg=<INTERRUPT_REGISTER> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays if chassis manager fails to download a new card. |
Event ID: 555 (Severity: Warning)
Message | chassis: RPS state: <ACTIVE/AVAILABLE/UNAVAILABLE/FAULTED>. Failures: |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays if chassis manager fails to download a new card. |
Event ID: 556 (Severity: Warning)
Message | chassis: RPS state: <ACTIVE/AVAILABLE/UNAVAILABLE/FAULTED>. Failures: |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays if chassis manager fails to download a new card. |
Event ID: 557
Message | Temperature back to normal. Failures: |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | Shows that the temp came back to normal. Sometimes message is overridden to print this: 'Temperature: Chassis Intake Air Normal' |
Event ID: 558 (Severity: Warning)
Message | <SLOT_NAME> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | chassis: Display a log of a NMI event when log only. |
Event ID: 559 (Severity: Warning)
Message | <SLOT_NAME> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | chassis: Display a log of a NMI event when log only. |
Event ID: 568
Message | chassis: External Power Supply connected, supplying XXX W of YYY W max. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an EPS is successfully plugged in |
Event ID: 569 (Severity: Warning)
Message | <SLOT_NAME>Ext Power Supply <GROUP_INDEX>: <pport> Failures: <port state>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an EPS reports an error condition to us |
Event ID: 570 (Severity: Warning)
Message | chassis: External Power Supply connected but not responding. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an EPS is plugged in but we can't talk to it |
Event ID: 572 (Severity: Warning)
Message | <SLOT_NAME> PoE usage has exceeded threshold of <start port> <end port>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the usage threshhold has been exceeded |
Event ID: 573 (Severity: Warning)
Message | chassis: External Power Supply disconnected. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an EPS is unplugged |
Event ID: 574
Message | <SLOT_NAME> PoE usage is below threshold of <start port> <end port>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when the usage threshhold has not been exceeded |
Event ID: 575 (Severity: Warning)
Message | <SLOT_NAME> Ext Power Supply <GROUP_INDEX> not supported by switch code. Please update. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an EPS is plugged in and SW does not support it |
Event ID: 576 (Severity: Warning)
Message | 50V Power Supply <GROUP_INDEX> is . Failures: <port state> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an EPS is plugged in and SW does not support it |
Event ID: 577 (Severity: Fatal)
Message | Ext Power Supply <GROUP_INDEX>: Failures: <port state>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when an EPS reports a fatal error condition to us |
Event ID: 578 (Severity: Warning)
Message | chassis: Unrecoverable fault on PoE controller X. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when PoE contrller has a fault we can't recover from. |
Event ID: 579
Message | <SLOT_NAME> Software update <port state> on PoE controller <GROUP_INDEX>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when PoE controller firmware is updated via software. |
Event ID: 634
Message | Front panel clear button pressed; switch reset. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when clear button resets box |
Event ID: 635
Message | Alternate password used to gain access. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when alt password is used. |
Event ID: 731
Message | Ports <SLOT_NAME> Recognized |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a fix slot is detected as inserted in an operational system. |
Event ID: 732 (Severity: Warning)
Message | Ports <SLOT_NAME> self test failure |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the indicated fix slot has failed selftest completely or when there are no usable ports on the fix slot. |
Event ID: 733 (Severity: Warning)
Message | Lost Communication with Ports <SLOT_NAME> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when Chassis Mgr. fails to receive a heartbeat response from a particular fix slave card. |
Event ID: 734
Message | Ports <PORT-NAME> Downloading |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager begins downloading a fix slot card. |
Event ID: 735
Message | Ports <PORT-NAME> Download Complete |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager finishes downloading a fix slot card. |
Event ID: 736 (Severity: Warning)
Message | Ports <PORT-NAME> Download Failed |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays if chassis manager fails to download a fix slot card. |
Event ID: 737
Message | Ports <PORT-NAME> Ready |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a fix slot slave card (StrongBad) goes into the state |
Event ID: 738 (Severity: Warning)
Message | Unable to Download to Ports <PORT-NAME> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays whenever a fix slot slave card has exceeded the number of download |
Event ID: 739 (Severity: Warning)
Message | Ports <PORT-NAME> may be Faulty |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays whenever the master does not receive a download request from |
Event ID: 740 (Severity: Warning)
Message | Backplane link to Ports <PORT-NAME> failed self test |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays whenever the backplane link to the fix slot failed selftest. |
Event ID: 741
Message | <SLOT_NAME> Ports Present |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager sees the fix slot module inserted. |
Event ID: 742 (Severity: Warning)
Message | Ports <SLOT_NAME> NCI Error IntReg=<INTERRUPT_REGISTER> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays if chassis manager fails to download a fix slot card. |
Event ID: 817 (Severity: Warning)
Message | <SLOT_NAME> self test failure |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the indicated slot has failed selftest and is unusable. |
Event ID: 818 (Severity: Warning)
Message | chassis: <SLOT_NAME> Invalid: This switch supports only "vl" modules |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the indicated slot is an invalid slot for vl. |
Event ID: 819 (Severity: Warning)
Message | <SLOT_NAME> Invalid: Module not supported by this software version |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when indicated slot is is not supported by this software version. |
Event ID: 829 (Severity: Warning)
Message | <SLOT_NAME> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | RTC: Battery Failure Detected -or; Clock Initializtion failure |
Event ID: 928
Message | Fabric <slot index> active |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when a fabric blade is able to actively pass traffic |
Event ID: 929 (Severity: Warning)
Message | Fabric <slot index> removed |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fabric blade is removed |
Event ID: 930 (Severity: Warning)
Message | Slot link failure: Fabric <MEMBER_NUMBER> has faulty link to <adjacent member number>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fault on a line card prevents it from connecting a link to a fabric. Error may be recoverable, but if persistant the linecard needs to be replaced. |
Event ID: 931 (Severity: Warning)
Message | Fabric failure: link error between Fabric <MEMBER_NUMBER> and <adjacent member number> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fabric blade is showed to have a faulty link to a Slot in the chassis. Error may be recoveralbe, but if persistant the Fabric needs field replacement. |
Event ID: 932 (Severity: Warning)
Message | chassis: Unknown fabric failure: link between Fabric <MEMBER_NUMBER> and <adjacent member number> down |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when the link between a fabric blade and a Slot has an error that can't be traced to either the fabric or the Slot without further testing. |
Event ID: 933
Message | Chassis running at reduced backplane capacity |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when we're operating with fewer active fabrics than required to maintain the backplane's full capacity. |
Event ID: 934 (Severity: Warning)
Message | Chassis has no active fabrics. Line cards resetting. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when there are no active fabric modules. (They are either not present, failed, or disabled.) |
Event ID: 935
Message | Fabric <MEMBER_NUMBER> disabled via configuration setting |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when a fabric blade is disabled via configuration setting. |
Event ID: 936
Message | Fabric <MEMBER_NUMBER> enabled |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when a fabric blade is enabled via configuration setting. |
Event ID: 937
Message | Fabric <MEMBER_NUMBER> inserted |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when a fabric blade is inserted (or first detected at boot time) |
Event ID: 938 (Severity: Warning)
Message | Fabric failure: Fabric <MEMBER_NUMBER> not responding |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fabric blade won't respond on the SRI. |
Event ID: 939 (Severity: Warning)
Message | Fabric failure: Fabric <MEMBER_NUMBER> failed selftest |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fabric blade fails selftest. |
Event ID: 940 (Severity: Warning)
Message | Fabric failure: Fabric <MEMBER_NUMBER> power failure |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fabric blade's power supply fails. |
Event ID: 941 (Severity: Fatal)
Message | <WHERE_INTERRUPT_OCCURRED> Fatal <WHICH_INTERRUPT_OCCURRED> F<which fabric the interrupt occurred on>: <HSL/NCI/ICL> Slot: <slot or port number> Status: <register value associated with the interrupt> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | HSL/NCI fatal interrupts from fabric |
Event ID: 942 (Severity: Warning)
Message | <WHERE_INTERRUPT_OCCURRED> Non-Fatal <WHICH_INTERRUPT_OCCURRED> F<which fabric the interrupt occurred on>: <HSL/NCI/ICL> Slot: <slot or port number> Status: <register value associated with the interrupt> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | HSL/NCI non-fatal interrupts from fabric |
Event ID: 2550
Message | Requesting Co-processor OS image location in flash. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager requests the slave OS image from the download task. |
Event ID: 2551 (Severity: Fatal)
Message | Failed to obtain Co-processor OS image location. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when the download task is unable to provide the slave OS image location. |
Event ID: 2552
Message | Loading of Co-processor OS image in progress. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager is getting the slave OS from flash, decompressing, and copying the OS into the slave area of RAM. |
Event ID: 2553
Message | Loading of Co-processor OS image complete. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager has completed copying the slave OS into the slave area of RAM. |
Event ID: 2554 (Severity: Fatal)
Message | Failed loading the Co-processor OS image. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when chassis manager has failed to copy the slave OS into the slave area of RAM. |
Event ID: 2555
Message | Co-processor Ready |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever the slave core (Samba) goes into the state of Available. |
Event ID: 2556
Message | Stack port <PORT_NUMBER> cable inserted. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a stack cable is inserted, in an operational chassis. |
Event ID: 2557
Message | Stack port <PORT_NUMBER> cable removed. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a stack cable is removed, from an operational chassis. |
Event ID: 2558
Message | Stack port <PORT_NUMBER> cable is on-line. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a stack port completes initialization, in an operational chassis. |
Event ID: 2559
Message | Stack port <PORT_NUMBER> cable is off-line. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a stack port is disabled or goes off-line, in an operational chassis. |
Event ID: 2560 (Severity: Warning)
Message | Stack port <PORT_NUMBER> cable initialization error. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays whenever a stack port fails for some reason, in an operational chassis. |
Event ID: 2561 (Severity: Warning)
Message | chassis: <MODULE> is not a supported Switch module. Please go to: http://www.arubanetworks.com/products/networking/ for more info. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an expansion module fails HPIDv2 authentication |
Event ID: 2563 (Severity: Warning)
Message | chassis: PoE controller X Reset. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when PoE contrller has been reset. |
Event ID: 2564 (Severity: Warning)
Message | PoE pre-std-detect mode is enabled. Power may be applied to non-PDs. Use only with legacy devices. To disable power on specific ports- use "no interface <PORT_LIST> power". |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when PoE pre standard detect is enabled. |
Event ID: 2565 (Severity: Warning)
Message | 50V Power Supply <PORT_NUMBER> AC Glitch. Glitches: <port state>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an IPS AC is interrupted but DC remains Ok. |
Event ID: 2568
Message | <STATE_RECORD> Core Dump Uploading |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager begins uploading a core dump from a new card. |
Event ID: 2569
Message | <STATE_RECORD> Core Dump Upload Complete |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when chassis manager finishes uploading the core dump from a new card. |
Event ID: 2570 (Severity: Warning)
Message | <STATE_RECORD> Core Dump Upload Failed |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays if chassis manager fails to upload the core dump from a new card. |
Event ID: 2750
Message | LEDs for module in slot <SLOT_NAME> configured OFF. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a module's LED's are configured to be off in savepower mode, in an operational chassis. |
Event ID: 2751
Message | LEDs for module in slot <SLOT_NAME> configured ON. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a module's LED's are configured to be on in normal mode, in an operational chassis. |
Event ID: 2752
Message | Ports on module in <SLOT_NAME> configured to low power mode. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a module's PHY are configured to Auto low power mode, in an operational chassis. |
Event ID: 2753
Message | Ports on module in <SLOT_NAME> configured to normal power mode. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a module's PHY are configured to normal power mode, in an operational chassis. |
Event ID: 2754
Message | Request for \"savepower module <SLOT_LIST>\". |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a slot is being powered down, in an operational chassis. |
Event ID: 2755
Message | Slot <SLOT_NAME> is powered down. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a slot is being powered down, in an operational chassis. |
Event ID: 2756
Message | Slot <SLOT_NAME> is powered up. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a slot is powered up, from the savepower mode, in an operational chassis. |
Event ID: 2757
Message | Savepower LED timer is ACTIVE. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever the timer for LED powersave feature becomes active, in an operational chassis. |
Event ID: 2758
Message | Savepower LED timer is SCHEDULED. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever the timer for LED powersave feature is scheduled, in an operational chassis. |
Event ID: 2759
Message | Savepower LED timer is OFF. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever the timer for LED powersave feature expires or is cancelled, in an operational chassis. |
Event ID: 2762
Message | Request for \reload module <SLOT_LIST>\". |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays whenever a slot is reloaded, in an operational chassis. |
Event ID: 2763
Message | Configuration removed for module in slot <SLOT_NAME>. |
Platforms | K, KB |
Category | Chassis |
Severity | Information |
Description | This message displays when a slot has been removed with the 'no module' command and the entire configuration for the module has been deleted. |
Event ID: 2765 (Severity: Warning)
Message | Unsupported mixed power supply types (PoE & PoE+) detected in chassis. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when mixed power supplies are present in the chassis (including RailHead) |
Event ID: 2766
Message | Supported same power supply types (PoE or PoE+) restored in chassis. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when single type (POE or POE+) power supplies are present in the chassis (including RailHead) |
Event ID: 2769 (Severity: Warning)
Message | <SLOT_NAME> Ext Power Supply <GROUP_INDEX> measured out of spec or is faulty. Please change or contact support. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an EPS is plugged in and SW reads invalid isrc value |
Event ID: 2777 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER> communication <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply has an internal communications error that results in running the PSU fans at max. |
Event ID: 2778 (Severity: Warning)
Message | Internal power supply <BAY_NUMBER>: Fan <FAN_NUM_FAULTED | FAN_NUM_OK>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fan on an internal power supply has failed. Power supply will still provide power and has not shut down. |
Event ID: 2779 (Severity: Warning)
Message | Internal power supply <BAY_NUMBER>: Output power <EXCEEDS | WITHIN> the threshold value. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a power supply's power output has exceeded a threshold. Power supply will still provide power and has not shut down. |
Event ID: 2780 (Severity: Warning)
Message | Internal power supply <BAY_NUMBER>: System current<EXCEEDS | WITHIN> the threshold value. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a power supply's system current has exceeded a threshold. Power supply will still provide power and has not shut down. |
Event ID: 2781 (Severity: Warning)
Message | Internal power supply <BAY_NUMBER>: PoE current <EXCEEDS | WITHIN> the threshold value. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a power supply's POE current has exceeded a threshold. Power supply will still provide power and has not shut down. |
Event ID: 2782 (Severity: Warning)
Message | Internal power supply <BAY_NUMBER>: Auxiliary inlet power is <FAN_NUM_FAULTED | FAN_NUM_OK>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a power supply's auxiliary power inlet has lost power. Power supply will still provide power and has not shut down. |
Event ID: 2783 (Severity: Warning)
Message | Internal power supply <BAY_NUMBER>: System power temperature <EXCEEDS | WITHIN> the threshold value. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a power supply's system power rail's temperature has exceeded a threshold. Power supply will still provide power and has not shut down. |
Event ID: 2784 (Severity: Warning)
Message | Internal power supply <BAY_NUMBER>: PoE power temperature <EXCEEDS | WITHIN> the threshold value. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a power supply's system power rail's temperature has exceeded a threshold. Power supply will still provide power and has not shut down. |
Event ID: 2785 (Severity: Warning)
Message | Internal power supply <BAY_NUMBER>: Inlet air temperature <EXCEEDS | WITHIN> the threshold value. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a power supply's inlet air temperature has exceeded a threshold. Power supply will still provide power and has not shut down. |
Event ID: 2786 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: Power usage <EXCEEDS | WITHIN> the threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's output power has exceeded a threshold. Power supply has shut down. |
Event ID: 2787 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: System <EXCEEDS | WITHIN> the current threshold value. Power supply<FAN_NUM_FAULTED | FAN_NUM_OK> Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's system power's current has exceeded a threshold. Power supply has shut down. |
Event ID: 2788 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: System <EXCEEDS | WITHIN> the voltage threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's system power's voltage has exceeded a threshold. Power supply has shut down. |
Event ID: 2789 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: Auxiliary PoE <EXCEEDS | WITHIN> the current threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's auxiliary POE power has exceeded its current threshold. Power supply has shut down. |
Event ID: 2790 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: Auxiliary PoE <EXCEEDS | WITHIN> the voltage threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's auxiliary POE power has exceeded its voltage threshold. Power supply has shut down. |
Event ID: 2791 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: Main PoE <EXCEEDS | WITHIN> the current threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's main POE power has exceeded its current threshold. Power supply has shut down. |
Event ID: 2792 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: Main PoE <EXCEEDS | WITHIN> the voltage threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's main POE power has exceeded its voltage threshold. Power supply has shut down. |
Event ID: 2793 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: Main inlet <EXCEEDS | WITHIN>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's main power inlet has lost power. Power supply has shut down. |
Event ID: 2794 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: PoE power <EXCEEDS | WITHIN> the temperature threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's POE power's temperature is too high. Power supply has shut down. |
Event ID: 2795 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER>: System power <EXCEEDS | WITHIN> the temperature threshold value. Power supply <FAN_NUM_FAULTED | FAN_NUM_OK>. Total fault count: <NUMBER_OF_FAULTS> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's POE power's temperature is too high. Power supply has shut down. |
Event ID: 2796 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER> <'inserted' or 'removed'>. Total fault count: <number of failures>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply has been removed. |
Event ID: 2797 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER> is <'ok' or 'faulted'>. Total fault count: <number of failures>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply has lost all power. |
Event ID: 2798 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER> main PoE power <'ok' or 'faulted'>. Total fault count: <number of failures> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's main POE source has lost power. |
Event ID: 2799 (Severity: Fatal)
Message | Internal power supply <BAY_NUMBER> auxiliary PoE power <'ok' or 'faulted'>. Total fault count: <number of failures> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when a power supply's auxiliary POE source has lost power. |
Event ID: 3360 (Severity: Fatal)
Message | Interface Module image id <slave image id> corrupted. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays if the slave image loaded during chassis bootup is corrupted. It could be the source corrupted or during the copy process to memory |
Event ID: 3802
Message | System Self test started on <'STAND_ALONE' OR 'MASTER'> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Event ID: 3803
Message | System Self test completed on <'STAND_ALONE' OR 'MASTER'> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Event ID: 3804
Message | System Self test failed on <'STAND_ALONE' OR 'MASTER'> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Event ID: 3831 (Severity: Warning)
Message | EEE cannot be enabled on <SLOT_NAME> on this hardware revision. |
Platforms | K, KA, KB, WB, WC, YA, YC |
Category | Chassis |
Severity | Warning |
Description | Port has been blocked by MSTP. |
Event ID: 3832 (Severity: Warning)
Message | <SLOT_NAME> Invalid: Module not supported in this quantity and/or slot configuration |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | Port has been unblocked by MSTP. |
Event ID: 3833 (Severity: Warning)
Message | <SLOT_NAME> Invalid: The module is not supported in this chassis. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | MSTP root port has changed. |
Event ID: 3834 (Severity: Warning)
Message | Power Supply <POWER_INDEX> <'inserted'> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | The number of configured MSTP instances exceeds the limit of instances permitted on a stack. |
Event ID: 3835 (Severity: Warning)
Message | Power Supply <POWER_INDEX> removed while <'powered' or 'not powered'> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | MSTP BPDU throttling is disabled because QinQ is enabled. |
Event ID: 3836 (Severity: Fatal)
Message | <WHERE_INTERRUPT_OCCURRED> Fatal <WHICH_INTERRUPT_OCCURRED> <WHICH_FABRIC_INTERRUPT_OCCURRED_ON>: <HSL/NCI/ICL> StackPort: <SLOT_OR_PORT_NUMBER> Status: <REGISTER_VALUE_ASSOCIATED_WITH_INTERRUPT> <SECONDARY_REGISTER_VALUE_ASSOCIATED_WITH_INTERRUPT> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | MSTP BPDU throttling is disabled because Meshing is enabled. |
Event ID: 3837 (Severity: Warning)
Message | <WHERE_INTERRUPT_OCCURRED> Non-Fatal <WHICH_INTERRUPT_OCCURRED> <WHICH_FABRIC_INTERRUPT_OCCURRED_ON>: <HSL/NCI/ICL> StackPort: <SLOT_OR_PORT_NUMBER> Status: <REGISTER_VALUE_ASSOCIATED_WITH_INTERRUPT> <SECONDARY_REGISTER_VALUE_ASSOCIATED_WITH_INTERRUPT> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | HSL/NCI non-fatal interrupts from fabric on stacking devs |
Event ID: 3838 (Severity: Warning)
Message | <SLOT_PORT> failed to boot. Timeout reached: <SOURCE> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Event ID: 3839 (Severity: Warning)
Message | <SLOT_NAME>: Lost Communications detected - <LOST_COMM_SOURCE> (<DLL_VALUE>2X) |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Event ID: 3840 (Severity: Warning)
Message | <name> module ROM Tomstone: <TOMBSTONE> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Event ID: 4050
Message | External power supply power-share request is completed. |
Platforms | WB |
Category | Chassis |
Severity | Information |
Description | Message displays when user change allocated power for PPS |
Event ID: 4051 (Severity: Warning)
Message | Unable to perform power-share as requested. Reason: <reason for failing>. |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when user's power allocation request could not be serviced |
Event ID: 4052
Message | External power supply connection status changed from <pps state> to <local cable status>. |
Platforms | WB |
Category | Chassis |
Severity | Information |
Description | Message displays when status of PPS changed |
Event ID: 4053
Message | External power supply has been restored to factory default. |
Platforms | WB |
Category | Chassis |
Severity | Information |
Description | Message displays when PPS has been restored to factory default |
Event ID: 4054 (Severity: Warning)
Message | There is a mismatch in power supply ratings between external power supply and this switch. External power supply configurations not allowed. |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when status of PPS PSU mismatch |
Event ID: 4055 (Severity: Warning)
Message | 12v standby rail on external power supply has failed. |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when 12v standby rail is bad |
Event ID: 4056
Message | External power supply power allocated has changed to <power per cable> watts by <pps over temp zone>. |
Platforms | WB |
Category | Chassis |
Severity | Information |
Description | Message displays when a xps POE power change is detected |
Event ID: 4057 (Severity: Warning)
Message | Over current has been detected on external power supply. <log> |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when PPS encountered over current |
Event ID: 4058 (Severity: Warning)
Message | Over temperature has been detected on external power supply. |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when PPS encountered over temperature |
Event ID: 4059 (Severity: Warning)
Message | Main power rail on external power supply has failed. |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when main rail is bad |
Event ID: 4060 (Severity: Warning)
Message | External power supply error: <specific error message> |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Event ID: 4061
Message | External power supply ready. |
Platforms | WB |
Category | Chassis |
Severity | Information |
Description | Message displays when PPS is ready |
Event ID: 4062 (Severity: Warning)
Message | Unsupported power supply configurations detected on external power supply.<EVENT_MSG> |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when PPS has an unsupported PSU inserted |
Event ID: 4063
Message | External power supply port is now in <'enabled' or 'disabled'> state. |
Platforms | WB |
Category | Chassis |
Severity | Information |
Description | Message displays when HSC on PPS is not turned on |
Event ID: 4064 (Severity: Warning)
Message | Unable to restore external power supply to factory default as requested. Reason: <EVENT_MSG> |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when PPS cannot be restored to factory default. |
Event ID: 4065
Message | External power supply zone record status: <EVENT_MSG> |
Platforms | WB |
Category | Chassis |
Severity | Information |
Description | Message displays when mailbox has been locked by another system |
Event ID: 4066
Message | External power supply power reduction completed. |
Platforms | WB |
Category | Chassis |
Severity | Information |
Description | Message displays when low priority power reduction is successful |
Event ID: 4067 (Severity: Warning)
Message | Unable to reduce external power supply power as requested. Reason: <EVENT_MSG>. |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when low priority power reduction failed |
Event ID: 4068 (Severity: Warning)
Message | Unable to control external power supply port <LOCAL_ZONE_OR_LOCAL_CABLE> as requested. Reason: <EVENT_MSG>. |
Platforms | WB |
Category | Chassis |
Severity | Warning |
Description | Message displays when HSC control cmd failed |
Event ID: 4069
Message | External power supply info: <EVENT_MSG> |
Platforms | WB |
Category | Chassis |
Severity | Information |
Event ID: 4070 (Severity: Warning)
Message | SD card self-test fail. Error code: <SD_CARD_RESULTS>. Reformat SD card from BootROM CLI. |
Platforms | KA, KB, WB, WC, YC |
Category | Chassis |
Severity | Warning |
Event ID: 4697 (Severity: Warning)
Message | Fabric failure: Link error between Member <STACK_MEMBER_NUMBER> Stack port <PORT_NUMBER> and Member <STACK_MEMBER_NUMBER> Stack port <PORT_NUMBER>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fabric error is detected on the stacking link that connects this member to another member in a backplane stack. Error may be recoverable, but if persistent the stacking cable, stacking module or chassis needs field replacement. |
Event ID: 4698 (Severity: Warning)
Message | Fabric failure: Uncategorized link error between Member <STACK_MEMBER_NUMBER> Stack port <PORT_NUMBER> and Member <STACK_MEMBER_NUMBER> Stack port <PORT_NUMBER>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a fabric error is detected on the stacking link that connects this member to another member in a backplane stack. Error may be recoverable, but if persistent the stacking cable, stacking module or chassis needs field replacement. |
Event ID: 4701 (Severity: Fatal)
Message | <SLOT_NAME>: fatal software error |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Event ID: 4702 (Severity: Fatal)
Message | <SLOT_NAME>: fatal software error |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Event ID: 5043 (Severity: Warning)
Message | Member <1-10>: Flexible Module <J_NUMBER> in slot <A or B> is inactive. Flexible Module <J_NUMBER> does not match configured <J_NUMBER>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an inserted expansion module is different than what has been provisioned for the slot in a stacking context. |
Event ID: 5044 (Severity: Warning)
Message | Flexible Module <J_NUMBER> in slot <A or B> is inactive. Flexible Module <J_NUMBER> does not match configured <J_NUMBER>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when an inserted expansion module is different than what has been provisioned for the slot in a standalone context. |
Event ID: 5045
Message | Member <1-10>: Flexible Module <J_NUMBER> inserted in slot <A or B> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an expansion module is inserted in a stacked switch. |
Event ID: 5046
Message | Flexible Module <J_NUMBER> inserted in slot <A or B> |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an expansion module is inserted in a standalone switch. |
Event ID: 5047
Message | Member <1-10>: flexible module <J_NUMBER> in slot <A or B> is active. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an inserted expansion module is powered up or inserted and becomes active in a stack. |
Event ID: 5048
Message | Flexible Module <J_NUMBER> in slot <A or B> is active. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an inserted expansion module is powered up or inserted and becomes active in a standalone switch. |
Event ID: 5049
Message | Member <1-10>: Flexible module <J_NUMBER> removed from slot <A or B>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an expansion module is unprovisioned in a stack. |
Event ID: 5050
Message | Flexible module <J_NUMBER> removed from slot <A or B>. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an expansion module is unprovisioned in a standalone switch. |
Event ID: 5053
Message | Member <1-10>: Savepower mode is enabled on <Flexible module A|B>. Flexible Module <J_NUMBER> in slot <A or B> is powered down. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an expansion module is powered down in a stack. |
Event ID: 5054
Message | Savepower mode is enabled on <Flexible module A|B>. Flexible Module <J_NUMBER> in slot <A or B> is powered down. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an expansion module is powered down in a standalone config. |
Event ID: 5055
Message | Member <1-10>: Savepower mode is disabled on <Flexible module A|B>. Flexible Module <J_NUMBER> in slot <A or B> is powered up. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an expansion module is powered up in a stack. |
Event ID: 5056
Message | Savepower mode is disabled on <Flexible module A|B>. Flexible Module <J_NUMBER> in slot <A or B> is powered up. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when an expansion module is powered up in a standalone config. |
Event ID: 5083
Message | Ports X-Y: PoE Software updated from version A to B. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when PoE controller firmware is updated successfully |
Event ID: 5084
Message | Ports X-Y: PoE Software update failed with error code A. Contact support for assistance. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | This message displays when PoE controller firmware update process fails. |
Event ID: 5173 (Severity: Fatal)
Message | System power failure |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Fatal |
Description | This message displays when Domain Power faults. |
Event ID: 5174 (Severity: Warning)
Message | System power recovered. Resetting system to restore operation |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays on a transition to Good Domain Power. |
Event ID: 5263
Message | Power fault detected on <MODULE>. |
Platforms | KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | Message will appear when a power fault is detected on an Expansion Module. |
Event ID: 5356 (Severity: Warning)
Message | MAC-level transmit error on port <PORT_ID>. If this reoccurs frequently- contact Technical Support. |
Platforms | K, KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | Too many MAC interrupts were received on a port. |
Event ID: 5570 (Severity: Warning)
Message | 5V power supply failure. <ADDITIONAL INFO> |
Platforms | KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a permanent 5V DC power fault occurs with additional information. Software is not able to restore 5V DC power. |
Event ID: 5571 (Severity: Warning)
Message | Power fault on USB port. |
Platforms | KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a 5V DC power supply fault occurs that is cleared by disabling the USB port. Causes for this fault include a faulty USB device or a fault in the USB port itself. |
Event ID: 5572 (Severity: Warning)
Message | Overcurrent detected on USB port. |
Platforms | KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Warning |
Description | This message displays when a USB over current fault occurs. This typically occurs when a faulty USB device has been installed. |
Event ID: 5573
Message | Normal operation restored on USB port. |
Platforms | KA, KB, RA, WB, WC, YA, YB, YC |
Category | Chassis |
Severity | Information |
Description | A USB over current condition has been resolved and normal operation has been restored on the USB port. |