Distributed Trunking Events
The following are the events related to distributed trunking.
Event ID: 3225 (Severity: Warning)
Message | Switch-interconnect link is down |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Warning |
Event ID: 3226
Message | Switch-interconnect link is up |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 3227
Message | Peer keep-alive link not configured. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 3228
Message | Peer keep-alive link is down. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | Keep alive link is down. Action: Enable DT ports on Secondary |
Event ID: 3229
Message | Peer keep-alive send is successful. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 3230
Message | Peer keep-alive send is failed. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | Keep alive link is down. Action: Enable DT ports on Secondary. |
Event ID: 3231
Message | Received keep-alive message from peer DT switch. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 3232
Message | Switch role is Primary. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | Keep-alive packet received. This switch is selected as Primary. No action is required. keep forwarding the traffic on DT ports. |
Event ID: 3233
Message | Switch role is Secondary- disabling all DT trunks. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | Keep alive pkt is recieved. This switch is selected as secondary; so disable all DT ports |
Event ID: 3234
Message | Failed to receive keep-alive messages from peer DT switch. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | Keep-alive timeout occurred. No action is required on primary. Enable DT ports on Secondary. |
Event ID: 3235
Message | Enabling all DT trunks. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | Enable DT ports when ISC is up or keepalive timeout occurred. |
Event ID: 3241 (Severity: Warning)
Message | Distributed-trunking keep-alive failed to bind receive socket. Default keep-alive UDP port(1024) is already in use. |
Platforms | KA, KB |
Category | Distributed Trunking |
Severity | Warning |
Description | DT Keepalive default UDP port(1024) already in use. |
Event ID: 3242
Message | Distributed-trunking keep-alive receive socket bind is successful. UDP port <DST_UDP_PORT> is used. |
Platforms | KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | DT Keepalive Receive Socket bind is successful. |
Event ID: 3303
Message | ISC protocol hello receive time is elapsed. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | ISC protocol has not received hello packets in 30 secs from the peer DT switch |
Event ID: 3304
Message | ISC protocol flow control is activated |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 3305
Message | ISC port <PORT_ID> is deleted from keepalive VLAN <VLAN_ID> |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | ISC will be deleted from a VLAN when the specific VLAN is configured as a keepalive VLAN. |
Event ID: 3306 (Severity: Warning)
Message | Trunk type mismatch detected on <TRUNK_NAME>- disabling <TRUNK_NAME> |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Warning |
Description | Keepalive VLAN mis-configuration is detected so reconfiguration is required. |
Event ID: 3307
Message | Keepalive mis-configuration detected. Reconfigure the keepalive VLAN |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | This message is logged when the role-priority change fails because the ISC is down. |
Event ID: 3308
Message | The configured role-priority will be in effect the next time ISC link goes offline. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Description | Keepalive with different version received from the peer DT switch. |
Event ID: 3309 (Severity: Warning)
Message | DT role will not be selected based on configured role priority. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Warning |
Event ID: 4691
Message | The peer keep-alive interval is reset to its default value <TIME_DEF_VAL> because the configured interval value <TIME_VAL> is greater than one-third of the keep-alive timeout value <TIME_VAL>. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 4692
Message | The peer keep-alive timeout is reset to its default value <TIME_DEF_VAL> because the configured timeout value <TIME_VAL> is less than thrice the keep-alive interval value <INTERVAL_STR>. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 5201
Message | Switch-interconnect link is In Sync. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 5202
Message | Switch-interconnect link is Out of Sync. |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Information |
Event ID: 5203 (Severity: Warning)
Message | Image version mismatch: peer switch image version =<REMOTE_SWITCH_VERSION>- local switch image version =<LOCAL_SWITCH_VERSION> |
Platforms | K, KA, KB |
Category | Distributed Trunking |
Severity | Warning |